2.29 METPRESS
Specify Air Pressure
The
metpress
command allows you to specify air pressure. Air pressure specified with the
metpress
command does not affect receiver operation. Rather, it allows you to create a record of atmospheric
conditions for post-processing purposes.
The
metpress
set
command specifies air pressure at
press
. This command only stores the pressure
value in volatile memory, and does not automatically generate a record. The humidity value can then
be displayed/recorded by requesting the
met
log.
The
metpress
clear
and the
metpress
default
commands clear the air pressure setting
.
Syntax
metpress
set [
press
]
metpress
default|clear
Message ID = 164
Table 38: METPRESS Default Configuration
Field
Data
Value Used if
Not Specified
Bytes
Format
Units
Offset
1
Header
-
-
-
0
2
Parameter Update, see
-
4
Enum
none
H
3
Pressure (in hectopascals or
kilopascals where:
1 kPa = 10 hPa)
0
4
Float
kPa or
hPa
a
a. You may use hPa or kPa in your float input depending on your preference
H+4
Parameter
Power-On
Freset
Stored in NVM
metpress
clear
clear
NO