4.  Follow the instructions on lubrication and proper replacement of tool accessories.  

 

5.  When not in use, prior to servicing and on changing accessories, switch off the tool and disconnect from the power 

source.  

 

6.  Prior to replacing accessories, the tool MUST BE removed from power source. DO NOT perform any servicing work on 

the tool when it is connected to the power source.  

 

7.  Regularly check pneumatic lines, electrical cords and replace them if they are damaged. Keep vertical handle and tool 

body dry, clean and free of oil and grease.  

 

CAUTION:

 

An unmaintained tool can cause accidents!  

 
SPECIAL SAFETY INSTRUCTIONS 

 
1.  Prior to operating the tool, always check for faulty and or defective parts. Never use the tool if it is damaged in any way. 

Any damaged safety features, starter lever or other faulty parts are to be repaired or replaced IMMEDIATELY before 
usage.  

 
2.  Always use both hands when operating the RotoStrip.  

 

CAUTION:

 

NOVATEK’s accessories are designed for use on RotoStrip tools and therefore should not be utilized on 

or in conjunction with any other machines. 

 

 

3.  After replacing any accessory check the adapter system for correct assembly before operating the machine.  
 
4.  For pneumatic model insure that sufficient length of air hose, supplied with a minimum of 5 SCFM compressed air at 90 

psi, is available. A supply of clean, dry air and suitable lubrication is recommended for trouble free use. Tighten all hose 
connector fittings and blow out hose to insure that all debris is purged from the supply line before use.  

 

5.  For electric model wipe down the outside surface of the drive motor enclosure to remove accumulated dirt, dust and 

other residue from preceding cleaning operation. Test run the motor to insure no arcing is indicated between the 
brushes. If arcing takes place and additional air jet cleaning does not correct the arcing, contact a 

NOVATEK

 

authorized distributor or 

NOVATEK

 directly by dialing 1-866-563-7800.  

 

6.  Check the compressed air at regular intervals to ensure the compressed air is clean and oiled. If it is necessary 

integrate a service until into the compressed air line.  

 

7.  If the tool is not in use, disconnect it from the air supply and store it in a suitable clean/dry location to prevent any 

unauthorized use.  

 

8.  ALWAYS hold both the tool body and the vertical handle while in use.  

 

9.  Keep in mind that brushes can create sparks while running on hard surfaces. Take precautions while in use.  

 

CAUTION:

 

ALWAYS wear eye protection to prevent injuries. 

 

 

10.  Never carry the tool by the air hose or power cord. Protect lines against heat, sharp edges and the possibility of running 

over while in use.  

 

11.  If the tool suddenly feels different, production level suddenly drops or produces a different noise, the tool should be shut 

down immediately and checked for any possible damage.  

 
 
 
 
 
 
 

SECTION V 

 
PLACING IN OPERATION 

Summary of Contents for Rotostrip ROTO100

Page 1: ......

Page 2: ...ssion from NOVATEK Corporation Making copies of this manual for any purpose other than your own personal use is a violation of the United States copyright laws January 1 2011 issue 1 0 Specifications...

Page 3: ...ile liquids such as kerosene diesel or jet fuel Use only recommended lubricants Keep work area clean uncluttered ventilated and illuminated Keep all electrical connections clear of water or other liqu...

Page 4: ...with inside trigger always be sure that the gloves will not prevent the trigger from being released Wear safety shoes hard hat safety goggles gloves dust mask and any other appropriate protective clo...

Page 5: ...PERSONAL SAFETY 6 SECTION IV TOOL CARE AND USAGE 6 SPECIAL SAFETY INSTRUCTIONS 7 SECTION V PLACING IN OPERATION 8 ABRASIVE BRUSH ASSEMBLY 8 ERASER WHEEL ASSEMBLY 9 SECTION VI SERVICE INSTRUCTIONS 9 TR...

Page 6: ...unit for any loose or damaged parts every time prior to use CAUTION Make sure power supply is off prior to inspection 1 Keep your working area clean from dirt and debris A cluttered working area is da...

Page 7: ...pply of clean dry air and suitable lubrication is recommended for trouble free use Tighten all hose connector fittings and blow out hose to insure that all debris is purged from the supply line before...

Page 8: ...rsa This can cause damage to the machine and operator 4 Start the tool by moving the safety stop forward and depressing the throttle level The throttle level will return to its initial position when i...

Page 9: ...enough SCFM e Check Panel Box circuit breaker f Add a few drops of oil to the compressed air connection and air inlet of pneumatic tool B If the machine is making an unusual sound a Check the same co...

Page 10: ...PLATE 24 BEARING 25 WASHER 26 BEARING 27 THREAD RING GEAR 28 IDLE GEAR 29 NEEDLE BEARING 30 IDLE GEAR PIN Ref Part No Description 31 GEAR PLATE 32 SLIDING KEY 33 BEARING 34 CLAMP NUT 35 BEVEL GEAR 36...

Page 11: ...n the outside the return merchandise authorization number All packages received without any R M A on the outside will be refused by NOVATEK CORPORATION receiving department Warranty claims will only b...

Reviews: