Novatek F0700 Operation And Maintenance Manual Download Page 5

 

*www.novatekco.com * toll free 866.563.7800 * tele 610.363.7800 * fax 610.935.1945 * [email protected]

 

SECTION I 

 

INTRODUCTION

 

 
This operation and maintenance manual is furnished with each 

NOVAIR 700

. It outlines the general use and 

maintenance requirements for efficient and safe operation. 
 

READ ALL INSTRUCTIONS AND DATA IN THIS OPERATION AND MAINTENANCE MANUAL PRIOR 

TO OPERATION OF THIS EQUIPMENT. 

 
These instructions are for your protection and convenience.  Please read them carefully. Failure to follow 
these precautions could result in injury or death.  Whenever using electric powered equipment, basic safety 
precautions should be followed. 
 
If after reading this manual you still have questions, contact a 

NOVATEK

 authorized distributor or 

NOVATEK

 directly by dialing 1-866-563-7800. 

 

SECTION II 

 

GENERAL DESCRIPTION

 

 
The

 NOVAIR 700

 is a portable, electrically powered Air Filtration machine, designed and manufactured by 

Novatek Corp. The machines function is to filter air and remove suspended airborne particulates.  
 
This unit has a three stage filtering system. The Pre-Filter (two-ply ring) stage captures the bulk of the dust 
and debris. The second Pleated Filter stage captures any dust and dirt able to penetrate the Pre-Filter. The 
final stage is the 99.99% - 0.3 micron HEPA Filter utilized in areas where an extremely high level of filtration 
is desired. 
 
The 

NOVAIR 700

 requires a 115V - 3 Amp / 230v-2 Amp single phase power source.  

 

WARNING 

Do not use circuits exceeding specified voltage. Higher voltage will damage controls and 

could cause shock or fire hazard. 
 

SECTION III 

 

ROUTINE MAINTENANCE

 

 
Inspect the unit for any loose or damaged parts prior to use.   

 

CAUTION:

  

Be sure power supply is in the OFF position prior to inspection! 

 

A.  Clean the surfaces of the unit to remove accumulated dust or dirt. Do not use petroleum distillates, 

solvents, or thinners as cleaning agents.  Remove any accumulated dust and dirt from control panel. 

B.  Periodic checks should be made of the 

panel’s Controls to insure proper operation. 

C.  Filters should be checked hourly/daily and replaced if needed. This will help ensure proper air flow and 

extend motor life.  

D.  Inspect ALL power connection. Be sure that the recessed plug is secure to the panel.  If recessed plug 

is not secured, electrical shock or shortage may occur. 

E.  Inspect the power cord connection for breaks, scorching, melting, oxidation, or signs of wear.  If cord 

shows 

ANY

 of these signs, it needs to be replaced. 

 

CAUTION:

  

Do not tamper with or modify the blower housing, control panel, drive motor, or wiring 

scheme. Tampering or modifications could result in premature wear or failure and will void factory 
warranty.  
 

Summary of Contents for F0700

Page 1: ......

Page 2: ...manual for any purpose other than your own personal use is a violation of the United States copyright laws March 1 2016 issue 1 0 Specifications subject to changes without notice If you have any ques...

Page 3: ...cles Some dust created by power sanding sawing and grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive harm Some examples o...

Page 4: ...ION I Introduction 5 SECTION II General Description 5 SECTION III Routine Maintenance 5 Control Descriptions 6 SECTION IV Prior To Use 7 Operation 7 SECTION V Replacement Of Filters 7 SECTION VI Wirin...

Page 5: ...ilter The final stage is the 99 99 0 3 micron HEPA Filter utilized in areas where an extremely high level of filtration is desired The NOVAIR 700 requires a 115V 3 Amp 230v 2 Amp single phase power so...

Page 6: ...maximum of 6 Amps when the unit is in the OFF position and 4 Amps when the unit is in the ON position You can attach other pieces of equipment to this but are limited to the maximum amp draw When the...

Page 7: ...ency of filter replacements Once the filters load and the pressure reaches approximately 3 the visual alarm will light CAUTION Always wear approved respirators and personal protective equipment during...

Page 8: ...is has a gasket the other does not Insert the side with the gasket of the HEPA filter first and press firmly against the housings internal rib F Install the housing filter frame and reinstall the 8 h...

Page 9: ...www novatekco com toll free 866 563 7800 tele 610 363 7800 fax 610 935 1945 sales novatekco com 9 WIRING DIAGRAM 230v...

Page 10: ...www novatekco com toll free 866 563 7800 tele 610 363 7800 fax 610 935 1945 sales novatekco com 10 SECTION VII Schematic...

Page 11: ...r death H Never operate the unit if there is any possibility of contact with the blower wheel I It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and effici...

Page 12: ...thorization number must be clearly marked on the outside of the package being returned Any returned merchandise that does not have a return merchandise authorization number clearly marked on the outsi...