Fault Lockout
After resetting the system the keypad display will
either display the ‘System Reset’ message, or it will
show a count of the faults which still exist. This is
called fault lockout.
These faults must be cleared before the system can
return to Day mode.
To see a list of the faults press the ENTER key. The
keypad will display each fault for 5 seconds. When all
of the faults have been displayed it will again display a
count of the faults. It will often be necessary to call out
the engineer in order to clear these faults.
If you can, clear the faults until the display shows no
faults, then press the ENTER key to return to Day
mode.
Remote Reset
If the system needs to be reset by an engineer code
you may need to call out the engineer. Before you do
this, check the SIS to see if either the
Remote Reset
or
Anti-code Reset
options have been enabled. If
either have been enabled it may be possible to reset
the system by following one of the procedures
described here:
Remote Reset
Your engineer will have given you instructions on how
to request a remote reset. Usually you will have to
telephone the central station, give details of the alarm,
and quote a password. The central station can then
reset your system via the signalling device which is
fitted to your system.
When the remote reset is received by your system,
the keypad will display the ‘System Reset’ message
for a few seconds. It will then either revert to the time
and date display, or display the number of faults
which still exist - this is a fault lockout.
Reset by Anti-code
If Anti-code reset has been enabled the keypad will
display the 4-digit Quote code. Make a note of this
number (it is different each time you use this facility)
and telephone your central station. You may need to
give details of the alarm and quote a password. You
will also need to quote the 4 digit number. The central
station will give you a 6 digit number called an
anti-code. Key in the anti-code to reset the system.
The keypad will either display the time and date, or it
will display the number of faults which still exist - this
is a fault lockout.
7
Karizma Plus
Quote Code
1400
System Reset by
STU
Faults: 1
ENTER to View
Faults: 0
ENTER to Exit
System Unset by
STEVE
Summary of Contents for KarizmaPlus
Page 15: ...Notes 15 Karizma Plus...