PRECESSION ELEPHANT 2 Scan Head 2
not OK
OK
5. If the above condition is
not
OK then set parameters
dx
and
dy
in node
Pens
default
HEAD
on tab
A Data
in group
Galvo offset
.
TIP
With each repetition of this step change only one parameter.
6. If it is necessary to set the
Galvo offset
to values of more than ± 1 % then the
laser beam has to be adjusted again, as described beginning with section
else
the scan head’s
Galvo offset
is set now.
7. Proceed with subsection
on page
6.7.4 Setting the ON and OFF delay
Tools
•
Laser safety glasses appropriate to the laser in use
•
Several sheets of metal with a thickness of 0.2 mm as a work piece
•
Microscope
Requirement
•
The nozzle incl. the protective glass has to be mounted to the scan head.
Procedure
1. Parametrize the laser for processing the work piece with minimal effect, i.e. with
average power and pulse repetition rate as low as possible.
2. Insert the work piece.
3. In the InScript software, load file
OnOffDelay.jobx
from the
Jobs\PrecessionElephant 1.3 and 2.0
folder of the
InScript Installation
.
52