2.4. Hazards
2. General safety instructions
WARNING
If the irradiance limit is exceeded, X-ray radiation emitting from the pro-
cessing point
can cause Cataract (lens clouding in the eye) and cancer.
• To avoid injury, follow the control measures and safety guidelines
provided by the laser’s manufacturer, and those established by
your Laser Safety Officer (LSO), Radiation Safety Officer (RSO), or
safety department of your business or institution.
2.4.5. HOT LASER-PROCESSED MATERIAL
During materials processing with lasers, strong heating of the processed ma-
terial may arise.
CAUTION
Hot laser-processed material
can cause skin burns.
• If you are a system integrator, then place a sign at the laser process-
ing area that warns about hot surfaces.
• When handling material by hand that was laser-processed shortly
before then wear heat resistant protective gloves.
2.4.6. ELECTROSTATIC DISCHARGE
The controller contains parts that are sensitive to electrostatic discharge.