Instruction Sheet
NovaLynx Corporation
PO Box 240 Grass Valley CA 95945
P a g e
|
2
Phone (530) 823-7185
www.novalynx.com
Power & Communications
1.
Connect the Power Adapter to a 100-240 Vac
receptacle to turn on the logger.
2.
Connect the RS232 cable to your computer.
If your computer does not have a DB9 serial
port, obtain a RS232 to USB adapter.
(NovaLynx 110-WS-16USB sold separately)
Logger Status
Use the up and down buttons below the display to toggle through
the Main Menu.
1.
Check the Date and Time.
2.
Check the logging interval, which is expressed in seconds.
3.
If correct, insert the memory card to begin logging. Otherwise
consult the instruction manual.
Note: serial data will be output
regardless of whether the memory card is installed or not.
View Sensor Data on the Logger
Scroll to Counter Channels, Analog Channels or Wind Channels and
then press the SELECT button. Within the sub-menus, press the up
and down buttons to view sensor data.
Counter Channels
2: Rain Today
Analog Channels
A0: Input Voltage, A4: Temperature,
A5: Humidity, A6: Barometric Pressure
Wind Channels
AN0: Wind Speed/Max, Wind Direction
View Sensor Data on a Computer
View data in 110-WS-25STR Graphical Display Software (sold separately) or in
a terminal program such as HyperTerminal, Putty, or TeraTerm. Select the
COM port, 9600 Baud, 8 data bits, no parity, no flow control. Sample data:
2021-01-02 01:58:22,1.9,7.0,4739,,,,,,,,,0.00,244,12.49,,,,10.3,82.5,,82.185,157,W603 ,1,0,155
Download Data
1.
Press inwards on the data card to release it.
2.
Insert the data card into the USB card reader (included). Connect the card reader to a computer.
3.
Open File Explorer to access the contents of the memory card. Copy any files you want to keep.
Note: The logger creates a new file every day, with the date code as the name (YYYYMMDD.csv).
4.
Open the file in a spreadsheet. It may be necessary to invoke "Text to Columns" to get the data to
fall into separate columns. The logger does not pre-pend column headings, so you will need to
create headings and copy/paste them into the spreadsheet to make it easier to interpret the data.
Wind Channels
<- SELECT ->
Analog Channels
<- SELECT ->
Counter Channels
<- SELECT ->
Status: LOGGING
00050/00060 sec
Date:
YYYY-MM-DD
Time:
HH:MM:SS
Main Setup Menu
<- SELECT ->
AN0, AN1, AN2
WIND DIRECTION
ANALOG INPUTS
A0 thru A7
COUNTERS
0, 1, 2
MAIN
MENU
CURRENT
DATA
Logger Setup
Menus
CONFIGURE
MENUS
110-WS-25 Logger
(back panel view)