© NovaCHARGE 2019 - All Rights Reserved
7
NC7000 Installation Manual
6
2.3 Mounting the Charging Station
NOTE:
If mounting onto a NovaCHARGE Universal Pedestal, please follow the
instructions that accompanied the pedestal.
To prepare for mounting, remove the mounting bracket from the back of the
charger by loosening the M4 screw.
2.4 NC7000 Series Charger Installation with NEMA 6-50 Plug
1.
Secure the main body mounting bracket to the wall (or pedestal) with the
appropriate screws.
In order to meet ADA requirements, please use the following heights:
• For an indoor site, the charger should be located no lower than 18” (450 mm) and
not higher than 48” (1.2m).
• For an outdoor site, it is not lower than 24” (609 mm) and not higher than 48”
(1.2m). Refer to Article 625, NEC.
Standard installation requires that only two screws are used to fasten the mounting
bracket, using the two middle screw holes. The additional screw holes may be used
based on individual requirements.
Figure 2-1 Fasten mounting bracket
Figure 2-2 Screw holes of mounting bracket
Screw sizing suggestion:
A. For masonry walls, use M6 mechanical screws. (Commercially Available)
B. For finished walls supported by wood studs, use #12 tapping screws.
(Model Accessories)
C. Please refer to the following torque. The actual torque is according to the
wall material.
2. Mount the NC7000 series charger onto mounting bracket.
• Slide the charging unit onto the mounting bracket.
• Fasten by tightening the M4 screw attached to mounting.
Please use the following torque.
Figure 2-3 NC7000 Series Charger and mounting bracket
Figure 2-4 Tighten M4 screw
Screw
Torque
M6
25 kgf.cm min
21.7 lb-in min
#12
25 kgf.cm min
21.7 lb-in min
Screw
Torque
M4
16 kgf.cm
13.88 lb/in