Page 1: ...Round Burner L INSTALLATION AND OPERATION GUIDE Before operating Bionova burner please read and follow instructions ...

Page 2: ... 1 standard in compliance with on our EECT technology and our experience and solutions from TUV certified BoxBurner L Dangerous goods Bioethanol fuel is classified as a flammable liquid Class 3 PG II and is regulated by various standards Please follow regulations in order to legally and safely store handle and use that sort of fuel Please inform yourself about regulations in your country ...

Page 3: ...stallation and Operation Guide Conditions of use 3 Warnings 4 Standard equipment received 6 Installation 7 Ventilation efficiency 10 Volume burning time 11 How to operate BIONOVA burner 12 Maintenance 16 Warranty 17 Data 18 Technology 19 ...

Page 4: ...ase use only specified fuel bioethanol Do not attempt to use any other flammable fluids as gasoline for example Round Burner L Porto is specifically designed for use with bioethanol and use of any other fuel would be extremely dangerous 4 Approval from building authorities may be required Please contact appropriate authorities before installing BIONOVA burner 5 Possession of fire extinguisher AMMO...

Page 5: ...burner Burner surface becomes intensively hot during burning and stays hot after burning for a long time 5 Indoor pollution BIONOVA burner have to be used in well ventilated areas product of bioethanol vapor burning is carbon dioxide can be dangerous in high saturations Persons with breathing problems should consult physician before installing BIONOVA burner 6 Do not use Round Burner L Porto as a ...

Page 6: ...ONOVA burner is not intended to be a sole continues heating source and to be used longer than 8 hours per session To avoid heat expansion and potential spilling please ensure that the burner is allowed to cool down completely on a regular basis 15 Using more than one Burner in the same space or a room or with other appliances that are burning bioethanol please consult with the manufacturer of the ...

Page 7: ...ent Received 6 Round Burner L Installation and Operation Guide The BIONOVA burner is supplied with following standard equipment 1 BIONOVA Round Burner L 1pc 2 Installation and operation guide 1Pc 3 Manipulation rod handle 1pc ...

Page 8: ...r is positioned in leveled position ISPRAVNO NE ISPRAVNO Avoid positioning a burner in the area of the room space with cross ventilation or a strong air flow this could result in irregular burning and fire hazard Plate on which burner is positioned must be rigid enough to withstand load of at least 10 Kg Do not install burner near any gas connections or pipe lines If do please make it safe by a pr...

Page 9: ...at tolerance Heat reflective panels ideally stainless steel should be installed as surrounding and top to assist heat distribution Glass or mirrored surfaces near BIONOVA burner must be toughened Closed volumes in the proximity of the burner must be kept ventilated Avoid any other materials or liquids beside fuel to enter in the burning pit area if that happens do not attempt to ignite it before a...

Page 10: ...Installation ENGLISH Round Burner L Installation and Operation Guide 9 Please find required installation dimensions 335 340 105 2 8 0 2 7 5 ...

Page 11: ...y open Minimum room volume Air exchange 1 h Explanation 350m3 0 2 Air exchange due to leakage in the building 140m3 0 5 Normal air exchange rate in the leak proof buildings 70m3 1 Complete air exchange in installation room during one hour Air exchange n h Comments 0 0 5 Windows doors closed 0 3 0 5 Window slightly open no shutters 0 5 1 Window open n h refers to ratio of air circulation in the roo...

Page 12: ... and Operation Guide 11 Volume burning time One full tank will burn up to 6 hours You may turn burner on and off at any time The efficiency data has approximate value depending on the model purchased weather conditions installation point and bioethanol used ...

Page 13: ... used in BIONOVA burner is bioethanol fuel no other fuel is allowed Recommended fuel NOVAFUEL All actions with managing bioethanol should be performed in well ventilated area and to be sure that all spillage is easily contained and away from any ignition source Volume In the center of the burner when you see fuel at the perforated area the tank is full 2 95 liters of fuel Avoid spilling or purring...

Page 14: ...ur hands and face away from the burner at all times during filling or igniting 5 At all times pure the fuel on the perforated area of the burner moving from one side of the opening to another avoid spilling or purring fuel because small misfire is possible 6 If spilling occurs please wipe it dry before any attempt to ignite a burner 7 You may use appropriate funnel to avoid spilling BIONOVA burner...

Page 15: ...ll Do not in any case put more fuel then maximum level when fuel is at the top of perforated area in the center of the burner Igniting BIONOVA burner Keep your hands and face away from BIONOVA burner at all time especially when igniting Before igniting make sure that the burner is clear and ready for use 1 Open lid to have enough ventilation for ignition 2 From safe distance with stretched arm put...

Page 16: ...l is used up there is no need to clean anything just wait for the burner to cool down then refill and restart Note When you see that the flame is small and reduced in the perforated area you can see the small flame that means that fuel level is at absolute minimum Reigniting BIONOVA burner 1 Check if the burner is on room temperature It takes from 15 30 min to cool down depending on how long it ha...

Page 17: ...ormal hot steel ageing process 1 Use a vacuum cleaner after approximately 50 liters of burned fuel to clean inside of the burner opening 2 Use a damp cloth or mild detergent without abrasives to clean burner surface 3 Do not let the detergent or polishing aperient to get into a burner opening especially perforated part since it can cause even more staining and smell during next use 4 After cleanin...

Page 18: ...l service and persons we do not except responsibility for operating the burner in these cases This warranty certificate along with the invoice or receipt must be presented when making any claim MODEL No SERIAL No PURCHASER DISTRIBUTOR Distributor stamp here DATE OF PURCHASE By signing I upper mentioned purchaser declare that I understand and will follow the terms of use presented in INSTALATION AN...

Page 19: ...teel Evaporator Ceramic fibers Tank Size 2 95 l Weight with full tank Up to 6kg Thermal output Up to 3 Kw Req room volume 70m3 Burning Time Continuously Up to 6 h The efficiency data has approximate value depending on the model purchased weather conditions installation point and bioethanol used ...

Page 20: ...nol Combustion Technology BIONOVA fireplace burners bringing to you unique technology of ethanol combustion EECT Our burner s combusting only ethanol vapors distributed from ceramic evaporator no loose fuel trough burning pit calibrated grill providing precise and odorless process of burning ...

Page 21: ...ENGLISH Note 20 Round Burner L Installation and Operation Guide ...

Page 22: ...Nova Vizantija Svetogorska 12 Belgrade Serbia T F 381 11 406 43 78 E info bionova com www bionova com ...