background image

 

ENGLISH

 

How to install the IoT environment properly 

 

22

 

Line Burner L Automatic – Installation and Operation Guide 

 

2.

 

Start the installed application. From the Home screen, select the QR 
code reading option: 

 

3. Read the QR code that you received from the BIONOVA info system on 
your secure e-mail address. 

4. Your BIONOVA burner application is ready to use. 

Summary of Contents for Bionova Line Burner L Automatic

Page 1: ...Line Burner L Automatic INSTALLATION AND OPERATION GUIDE Before operating Bionova burner please read and follow instructions ...

Page 2: ...e burner is designed and produced accorded to new DIN 4734 1 standard Dangerous goods Bioethanol fuel is classified as a flammable liquid Class 3 PG II and is regulated by various standards Please follow regulations in order to legally and safely store handle and use that sort of fuel Please inform yourself about regulations in your country ...

Page 3: ...ditions of use 3 Warnings 4 Standard equipment received 6 Installation 7 Connecting ventilation 10 Ventilation thermal efficiency burning time 11 How to operate BIONOVA burner 12 Maintenance 16 Warranty 17 Burner data 18 Technology 19 How to install the IoT environment properly 20 ...

Page 4: ...Please use only specified fuel bioethanol 96 Acc Do not attempt to use any other flammable fluids as gasoline for example BIONOVA Burner is specifically designed for use with bioethanol and use of any other fuel would be extremely dangerous 4 Approval from building authorities may be required Please contact appropriate authorities before installing BIONOVA burner 5 Possession of fire extinguisher ...

Page 5: ...may cause serious burns 4 Never put flammable objects on the burner Burner surface becomes intensively hot during burning and stays hot after burning for a long time 5 Indoor pollution BIONOVA burner have to be used in well ventilated areas product of bioethanol vapor burning is carbon dioxide can be dangerous in high saturations Persons with breathing problems should consult physician before inst...

Page 6: ...lified persons or has been changed or altered in any way 14 BIONOVA burner is not intended to be a sole continues heating source and to be used longer than 8 hours per session To avoid heat expansion and potential spilling please ensure that the burner is allowed to cool down completely on a regular basis 15 Using more than one Burner in the same space or a room or with other appliances that are b...

Page 7: ...Burner L Automatic Installation and Operation Guide The BIONOVA burner is supplied with following standard equipment 1 BIONOVA Line Burner L Automatic 1pc 2 Installation and operation guide 1pc 3 Electronic control unit 1pc 4 Remote control 1pc ...

Page 8: ...correct way of positioning It is necessary to provide ventilation openings on the cube in which the burner is installed in order to ensure even air circulation and prevent overheating of the burner body and avoid possible damage to the burner Before installing the burner the interior of the cube in which the burner is placed must be cleaned of construction dust and similar impurities Building dust...

Page 9: ...tly beside wallpaper or laminate or any other non fire proof surface or material Be installed into a setting that has square back corners can influence aerodynamics and cause flame to behave irregularly As a general guide we recommending Any furniture items or fittings placed directly above or beside BIONOVA burner should be suitable for heat tolerance Heat reflective panels ideally stainless stee...

Page 10: ...Installation ENGLISH Line Burner L Automatic Installation and Operation Guide 9 Please find required installation dimensions 705 710 1 8 5 1 9 0 maximum 20 ...

Page 11: ...Connect power cable 3 from electronic driver unit to the grounded power supply 220V 230V 3 Place the burner and test the functionally Ventilation When proper fuel is used BIONOVA burner do not need any permanent fixture or fitting chimney gas line or any utility or supply Products of burning bioethanol vapors are CO2 water steam and heat Optimum room volume per a burner is 70m 3 If used in smaller...

Page 12: ...ors closed 0 3 1 Window slightly open no shutters 0 5 1 Window open n h refers to ratio of air circulation in the room example 0 5 h means that half of the air in the room is replaced every hour Efficiency BIONOVA burner is efficient since all the heat stays in the room rather than be wasted to residual emissions You may turn burner on and off at any time Volume Burning time One full tank will bur...

Page 13: ...l NOVAFUEL All actions with managing bioethanol should be performed in well ventilated area and to be sure that all spillage is easily contained and away from any ignition source Volume In the center of the burner inside of perforated area when you see fuel at the bottom of the perforated are tank is full 2 95 liters of fuel When filling fuel in the tank the slide mechanism flap of the burner must...

Page 14: ...ppropriate funnel to fill up the tank 5 Keep your hands and face away from the burner at all times during filling or igniting 6 If spilling occurs please wipe it dry before any attempt to ignite a burner 7 You may use appropriate funnel to avoid spilling Open the sliding mechanism flap all the way button A on the remote control the perforated surface is reviled Charge the burner slowly without spi...

Page 15: ...have enough ventilation for ignition by pressing push button A on a remote control 2 From safe distance at least 1m press push button C on a remote control and hold for few seconds If ignition is not achieved please press and hold push button C again for few seconds Do not hold push button C for more than 10 seconds continuously 3 Strong and stable flames will be achieved approximately 1 2 minutes...

Page 16: ...n refill and restart Note When you see that the flame is small and reduced in the perforated area you can see flame only from sides of the burning pit that means that fuel level is at absolute minimum Reigniting BIONOVA burner 1 Check if the burner is on room temperature It takes from 15 30 min to cool down depending on how long it has been used before 2 Pressing push button A on a remote control ...

Page 17: ...el ageing process 1 Use a vacuum cleaner after approximately 50 liters of burned fuel to clean inside of the burner opening 2 Use a mild detergent to clean burner surface If the surface is highly stained apply mild polishing aperient without abrasives 3 Do not let the detergent or polishing aperient to get into a burner opening especially perforated part since it can cause even more staining and s...

Page 18: ...al service and persons we do not except responsibility for operating the burner in these cases This warranty certificate along with the invoice or receipt must be presented when making any claim MODEL No SERIAL No PURCHASER DISTRIBUTOR Distributor stamp here DATE OF PURCHASE By signing I upper mentioned purchaser declare that I understand and will follow the terms of use presented in INSTALATION A...

Page 19: ...Main material Stainless Steel 1 4301 Evaporator Ceramic fibers Tank Size 2 95 l Weight 1 kg Thermal output Up to 3 Kw Req room volume 70m 3 Burning Time Continuously Up to 6 h The efficiency data has approximate value depending on the model purchased weather conditions installation point and bioethanol used ...

Page 20: ... Combustion Technology BIONOVA bioethanol fireplace burners are bringing to you unique technology of ethanol combustion EECT Our burner s combusting only ethanol vapors distributed from ceramic evaporator no loose fuel trough burning pit calibrated grill providing precise and odorless process of burning ...

Page 21: ... Blynk A key in the form of a QR code represents confidential electronic information that can be misused therefore please keep your QR code with care do not share it with users who might abuse the ability to use or incorrectly use your BIONOVA burner Please contact BIONOVA info service by sending a request for QR code from your secure e mail address to BIONOVA info service info bionova rs Although...

Page 22: ...e following parameters SSID BioNova burner Password bio123nova Authentication Method WPA2 Personal After plugging the power cord into a socket 220V necessarily grounded the control unit will automatically connect via WiFi to the access point You may check the connection in the network folder section of your router Your BION s burner will be identified as ESP _ Installing the Blynk application 1 In...

Page 23: ...omatic Installation and Operation Guide 2 Start the installed application From the Home screen select the QR code reading option 3 Read the QR code that you received from the BIONOVA info system on your secure e mail address 4 Your BIONOVA burner application is ready to use ...

Page 24: ...Nova Vizantija Svetogorska 12 Belgrade Serbia T F 381 11 406 43 78 E info bionova com www bionova com ...

Reviews: