3.5 Wiring diagrams
3.5.1 Connection layout
Relation between temperature (°C) and nominal resistance (Ohm) of CH probe SR and DHW probe SS.
T (°C)
0
2
4
6
8
0
27203
24979
22959
21122
19451
10
17928
16539
15271
14113
13054
20
12084
11196
10382
9634
8948
30
8317
7736
7202
6709
6254
40
5835
5448
5090
4758
4452
50
4168
3904
3660
3433
3222
60
3026
2844
2674
2516
2369
70
2232
2104
1984
1872
1767
80
1670
1578
1492
1412
1336
90
1266
1199
1137
1079
1023
pic. 21
26
F1 BIT
Bi-thermal heat exchanger boiler
F2 PIA
Mono-thermal heat exchanger boiler
F3 RIS
CH only boiler
F4 BOL System boiler
F5 MIC
Micro-reservoir boiler
F6 MAC “AQUA PREMIUM “ boiler
M3-M8-M9: Power supply connector, TA
external probe
M16 :
Tele-metering connector
M2-M15 : Boiler components connectors
E.RIV :
Detection electrode
E.ACC : Ignition electrode
P :
Water pump
V :
Fan (TFS models only)
MVD :
Three-way valve motor
DK :
Low water pressure switch
SR :
CH probe (10 Ohm B = 3435)
SE :
External temperature probe (10 Ohm
B = 3977 - Option)
SS :
DHW probe (10 Ohm B = 3435
three metre max. length)
TA :
Room thermostat (option)
CM1-CM2 : Boiler type selection jumpers
FL :
Flow sensor
VG :
Gas valve
TL :
Limit thermostat
PV :
Fan pressure switch (TFS models only)
TF :
Flue leak detection thermostat
(TN model only)
B :
Probe-equipped external cylinder
(remove
R1)
B1 :
Bulb probe-equipped external water
cylinder (remove P1)
TIMER : DHW programmer (remove P1 when
timer is installed)
P1 :
Timer priority jumper
R1 :
10k Ohm resistance
S :
Bulb probe
TR.ACC : Ignition transformer