Nouvag TCM Endo III Operation Manual Download Page 4

NOUVAG AG 

 

TCM Endo III 

 

No. 31817   29/05 

 

 

2  Safety measures 

Your safety, the safety of your team, and, it goes without saying, the safety of your patients is for Nouvag 
AG the first priority. It is therefore vital that the following measures be strictly observed: 

 

• 

The TCM Endo III should be operated by qualified personnel only! 

• 

Check the correct operation voltage on the rating plate! 

• 

Responsibility  for  the  use  of  accessories,  parts  or  assemblies  from  other 

manufacturers rest solely with the user! 

• 

Repairs  are  to  be  carried  out  by  authorized  Nouvag  AG  service  technicians 

only! 

• 

Nouvag  AG  cannot  be  held  liable  for  any  malfunction  of  the  TCM  Endo  III,  or 

performance  failure  and/or  its  designed  or  desired  utility,  nor  can  Nouvag  AG 
be  held  liable  for  any  injuries  to  persons  or  animals,  in  any  case  when  the 
device is miss-used or not operated, applied or maintained in strict accordance 
with  the  user/owner  instructions  set out in the operating manual. In the event 
of  any  doubt  or  question,  the  user  is  to  contact  Nouvag  AG  or  its  lawful 
representative for clarification or assistance! 

3  Shipping contents 

1520 ........................... Control unit TCM Endo III ........................................................................... 1 piece 
1823 ........................... Micromotor Endo ........................................................................................ 1 piece 
1488 ........................... On / Off -Footswitch.................................................................................... 1 piece 

4  Set-up 

1)  Connect On/Off-footswicht to “FOOT“  

(

 when operating unit with footswitch) 

2)  Connect the micromotor to “MOTOR“ 

3)  Attach handpiece or contra angle 

4)  Attach AC cord into the plug in the back of the unit and the electrical outlet 

5)  Turn on green power “ON / OFF“ switch (rear of unit) 

6)  Adjust desired reduction and speed. 

7)  Press “MOTOR“-key or step on the foot switch (if foot switch is connected) to start the micromotor. 

Summary of Contents for TCM Endo III

Page 1: ...NOUVAG Made in Switzerland Nr 31817 www nouvag com Operation manual GB TCM Endo III ...

Page 2: ...d Storage Environment 2 1 5 Description on device 2 2 Safety measures 3 3 Shipping contents 3 4 Set up 3 5 Operation 4 5 1 The TCM Endo III unit 4 5 2 The footswitch 5 5 3 Automatic Limiter AL 5 5 4 Automatic Protection AP 5 5 5 Memory 6 6 Disinfection Cleaning and sterilization 6 6 1 Control unit and footswitch 6 6 2 Mikromotor Endo 7 7 Troubleshooting 7 8 Disposal 7 ...

Page 3: ...l preparation With use of the AP mode file stress is greatly reduced 1 2 Technical Data Voltage 115V 50 60Hz or 230V 50 60Hz see device label Fuses 2 x T2A for 115V and 2 x T1A for 230V Power 40 VA Type Application part type B Speed 1 200 16 000 rpm Dimension 90 x 100 x 170 mm Net weight 2 kg 1 3 Operating Environment Relative Humidity max 80 Temperature 10 to 40 C Barometric Pressure 800 to 1060h...

Page 4: ... nor can Nouvag AG be held liable for any injuries to persons or animals in any case when the device is miss used or not operated applied or maintained in strict accordance with the user owner instructions set out in the operating manual In the event of any doubt or question the user is to contact Nouvag AG or its lawful representative for clarification or assistance 3 Shipping contents 1520 Contr...

Page 5: ...r reduce torque Rev Forw To change motor direction of rotation a warning tone will sound when the motor operates in reverse mode 1 1 Press this key if using handpiece 1 1 Speed from 1 200 to 16 000 rpm Torque 1 2 3 4 5 7 10 13 16 19 Nmm 8 1 Press this key if using contra angle 8 1 Speed from 150 to 2 000 rpm Torque 2 4 6 10 15 20 25 30 40 50 Nmm 16 1 Press this key if using contra angle 16 1 Speed...

Page 6: ...20 2 Pressing the keys and will increase and decrease the torque level respectively 3 By pressing the ATC SET briefly once more the digital display switches back automatically 5 4 Automatic Protection AP The automatic protection AP mode is a special function against file breakage When the selected torque level is reached the motor reverses immediately to free the file and then returns automaticall...

Page 7: ...olving agents for cleaning Autoclave material in transparent packaging Do not fill the sterilization bag more than 80 Autoclave material at 134 C maximum Sterilized material should be stored and tagged with sterilization date 6 1 Control unit and footswitch The control unit and the pedal do not come into contact with patients Only clean the surface of the unit do not use harsh cleaners or solvents...

Page 8: ...properly Insert plug and check fitting Wrong operating voltage Check mains voltage output please see operating voltage on the rating plate Footswitch fails to function Pedal not connected Plug pedal cable into rear of control unit Control unit not turned on Turn main switch ON OFF Micromotor does not run Motor not turned on Turn motor with Motor key on or with footswitch Motor not connected Connec...