FDM-1 Dual Monitor Module

INSTALLATION  AND  MAINTENANCE  INSTRUCTIONS

Before Installing

This  information  is  included  as  a  quick  reference  installation 
guide. Refer to the control panel installation manual for detailed 
system information. If the modules will be installed in an existing 
operational system, inform the operator and local authority that 
the system will be temporarily out of service. Disconnect power to 
the control panel before installing the modules.

NOTICE: 

This manual should be left with the owner/user of this 

equipment.

General Description

The Dual Monitor Module is intended for use in intelligent, two 
wire systems. It provides two independent 2-wire initiating device 
circuits (IDC), at two separate, consecutive addresses. It is capable 
of monitoring normally open contact fire alarm and supervisory 
devices, or either normally open or normally closed security de-
vices. The module has a single panel controlled red LED.

Compatibility Requirements

To ensure proper operation, this module shall be connected to a 
compatible Notifier system control panel (list available from Noti-
fier).

Mounting

Mounts directly to 4” square electrical boxes (see Figure 2A). The 
box must have a minimum depth of 2

1

/

8

”. Surface mounted elec-

trical boxes (SMB500) are available from Notifier.

Wiring

NOTE:

    All  wiring  must  conform  to  applicable  local  codes,  or-

dinances, and regulations. This module is intended for 
power limited wiring only.

1.  Install module wiring in accordance with the job drawings and 

appropriate wiring diagrams.

2.  Set the address on the module per job drawings.
          Note: Some panels support extended addressing. In order 

     to set the module above address 99 on compatible systems, 
     carefully remove the stop on the upper rotary switch with  
     thumb in the direction shown in Figure 1.

      

Note:  Monitor  module  L  (using  terminals  6  and  7)  re-
sponds  at  the  address  set  on  the  code  switches.  Monitor 
module H (using terminals 8 and 9) will automatically re-
spond at the next higher address. For example, if the code 
switches are set to 76, module L will respond at address 76 
and module H will respond at address 77. Use caution to 

Figure 2A. Module mounting:

Figure 2B: 

Specifications

Normal Operating Voltage:                    15 to 32 VDC
Maximum Current Draw:                      5.7 mA (LED on)
Average Operating Current:                   750µA (LED flashing)
EOL Resistance:                                    47K Ohms
Maximum IDC wiring resistance:           1,500 Ohms
Temperature Range:                              32˚F to 120˚F (0˚C to 49˚C)
Humidity:                                            10% to 93% Noncondensing
Dimensions:                                         4

1

/

2

 H x 4

 W x 1

1

/

4

 D (Mounts to a 4

 square by 2

1

/

8

 deep box.)

Accessories:                                         SMB500 Electrical Box

12 Clintonville Rd

  Northford, CT 06472-1653

(203) 484-7161

Figure 1. Removing
Rotary Switch Stop:

A78-2611-19

A78-2610-14

A78-2318-13

9
8
7
6
5

4

3

2

1

0

TENS

ONES

ADDRESS

LOOP

0

7 8

6

5

4

3

2

1

9

10

11

12

13

14

15

0

2

4

6

8

0

1

2

3

4

9

8

7

6

5

0

TENS

ONES

ADDR

ESS

LOOP

8

6

4

2

0

9

8

7

6

5

4

3

2

1

10

11

12

13

14

15

avoid duplicate addressing of modules on the system.

3.    Secure module to electrical box (supplied by installer), as 

shown in Figure 2A.

www.PDF-Zoo.com

Reviews: