Read Status
Aspiration Detector
3.5 Aspiration Detector
When a detector address is entered into the Point Select Screen and the ACCEPT soft key is pressed, the following screen will display if
the detector is an aspiration detector.
Figure 3.6 Aspiration Detector Screen - Read Status
Display
Lines 1 through 14 - Refer to the descriptions in Section 3.2, “Smoke Detector”, on page 35.
Line 15 - The current time and date are displayed in this line.
Line 16 - Press BACK to return to the previous screen.
3.6 Monitor Module
When a module address is entered into the Point Select Screen and the ACCEPT soft key is pressed, the following screen will display if
the point is a monitor module.
Figure 3.7 Monitor Module Screen - Read Status
Display
Lines 1 through 10 - Refer to the descriptions in Section 3.2, “Smoke Detector”, on page 35.
Line 12 - When a Read Status is performed on an FMM-4-20 module, the current 4-20 mA sensor’s reading will be displayed in the units
specified in point programming.
Lines 13 and 14 - When a module is monitoring an AMPS-24, ACPS-610/E, or an ACPS-2406, information will appear in these lines in
the following format.
BATTERY VOLTAGE: 27.9 VOLTS
CHARGER CURRENT:
0.0 AMPS
Line 15 - The current time and date are displayed in this line.
Line 16 - Press BACK to return to the previous screen.
L A K E V I E W G E N E R A L H O S P I T A L
S Y S T E M N O R M A L
1 0 : 2 2 : 3 4 A
T U E J A N 2 8 , 2 0 1 3
R E A D A D D R E S S : L 0 3 D 0 5 2
A U T O M A T I C
I N A C T I V E
E L E V A T O R L O B B Y
E A S T W I N G
F I F T H F L O O R
Z 0 0 5
A S P I R A T I O N
Z 0 0 5 ,
Z 0 2 7 ,
Z 0 6 6 ,
,
,
,
,
,
,
,
V A L U E S : 0 1 1 % O F A L A R M
A C T I O N / S T A T U S : N O N E / V E R Y C L E A N
P E A K S = 5 6 % C O U N T : 0 2 T E M P :
1 0 : 2 2 : 3 4 A
T U E J A N 2 2 , 2 0 1 9
B A C K
L A K E V I E W G E N E R A L H O S P I T A L
S Y S T E M N O R M A L
1 0 : 2 2 : 3 4 A
T U E J A N 2 2 , 2 0 1 9
R E A D A D D R E S S : N 1 2 4 L 0 3 M 0 5 2
A U T O M A T I C
I N A C T I V E
E L E V A T O R L O B B Y
E A S T W I N G
F I F T H F L O O R
Z 0 0 5
P U L L S T A T I O N
Z 0 2 2 ,
Z 0 2 7 ,
Z 0 6 6 ,
,
,
,
,
,
,
,
1 0 : 2 2 : 3 4 A
T U E J A N 2 2 , 2 0 1 9
B A C K
Battery voltage
and charger
current will appear
in lines 13 and 14
if the module is
monitoring an
AMPS-24, ACPS-
610/E, or an
ACPS-2406. See
text below.
Current 4-20mA
sensor readings
will appear in line
12. See text below.