InsTallaTIon
Pristine series installation and oPeration Manual • 2011
9
identifying Main Components
(see drawings on page 8)
no. description
1
Baffle
2
Red Indicator Light
3
On/Off Switch
4
Temperature Control
5
Loading Door
6
Latch Catch
7
Ash Clean Out Door
8
Ash Tray
9
Secondary Burn Chamber
10
Heat Exchange Flues
11
Door Lock Bar
12
Exhaust Exit Lever
13
Vent Cap & Water Level Indicator
14
Moulded Brick
15
S 70 Brick
16
1/2 Brick
17
Fire Brick
18
Smoke Exit Connector Bar
19
Switch Trigger
20
Air Gate
21
Overflow
22
Side Panel
23
Smoke Exit Connector Bar
24
Smoke Exit Lid
25
Extension Leg (optional)
26
Leg Brace (optional)
27
Ash Rake
28
Flue Cleaning Rods
29
Flue Cleaning Brush
30
Electric Element Ports
31
Return Port
32
Drain
33
Burner Mount Cover
34
Supply Port
35
Blower
36
Timer
37
Exhaust Area
38
Flapper Unit
39
Exhaust Flange
40
Relays
41
Limit Switches
42
Lifting Hook
43
Top Panel
44
Low Water Cut Off Port/Probe Well B
45
Snap Disc/Furnace Manual Reset
46
Temperature Probe Well A
47
Pump Snap Disc
48
Probe Port
49
Flue Clean Out Cover
50
Rear Access Cover
51
Furnace Electrical Plug
52
Pump Plug
optional: low water cut off switch kit. ask your dealer for details.
Minimum Clearance to Combustibles
Side Wall to Furnace
12” (305 mm)
Back Wall to Furnace
12” (305 mm)
Front of Furnace to Combustibles
48” (1220 mm)
Flue Pipe
12” (305 mm)
Ceiling to Furnace
24” (610 mm)
Floor
0” (0 mm)
installation requirements
1. The Pristine must be installed on a level stable surface,
preferably on a concrete floor but may be installed on
a combustible floor provided that a noncombustible liner
(such as sheet metal or masonry) be placed on the floor,
ensuring the following areas are covered to catch stray
embers:
- Underneath the furnace;
- At least 16” (406 mm) in front and 8” (203 mm) on
either side of the fuel loading and ash removal doors;
- Underneath the chimney connector and extending
at least 2” (50 mm) on either side of the chimney
connector.
2. Adhere to minimum clearance to combustibles as stated
in this manual and in accordance with local, state,
provincial and federal building and fire codes.
3. Install in a large open area when possible. Minimum
enclosed, not well vented, room size is 100 square feet
(9.3m
2
).
4. Room must be vented to outside air, see page 11.
iMPortant:
Contact an insurance provider prior to
installation to ensure that installation is in compliance with
local insurance requirements and all terms have been met.