ONL673L 7/13
11
Figure 6-B: Series 3 Generator Control Panel
Control Panels
Figure 6-A: Series 1-B Generator Control Panel
Figure 6-C: Series 4 Generator Control Panel
1. SHUTDOWN BYPASS-PREHEAT SWITCH
There are two functions built into this switch:
preheating the engine and bypassing the engine safety
shutdown circuit, enabling a start. Hold the switch in
the ON position for approximately 10 to 20 seconds
before starting a cold engine. Holding the switch ON for
too long can burn out the glow plugs.
NOTE: Three position Engine Control switches must be
in the RUN position during preheating. Preheat switch
must be held in ON position during starting.
2. ENGINE CONTROL SWITCH
To start the engine, hold this switch in the START
position until the engine is running.
NOTE: Excessive cranking of marine sets equipped
with water lift muffl er systems can cause engine
damage. See page 8.
After the engine starts, release the switch and it will
return to RUN position. To stop the engine, hold the
switch in the STOP position.
NOTE: The rocker switch is used on Series 1 panels
only, and has a light that glows when the set is running.
3. HOUR
METER
Keeps track of engine running time.
4. OIL PRESSURE GAUGE
Shows the oil pressure in the engine lubricating system.
5. WATER TEMPERATURE GAUGE
Registers the temperature of the cooling water.
6. D.C. VOLTMETER OR AMMETER
When the engine is stopped, the voltmeter indicates the
condition of the battery. When the engine is running, the
voltmeter indicates the voltage output of the alternator.
For Series 4 Control Panels Only:
7. A.C.
VOLTMETER
Shows the generator output voltage.
8. FREQUENCY METER (Hertz)
The frequency meter indicates engine speed: 1200 or
1800 RPM (60 Hz), or 1500 RPM (50 Hz).
9. AMMETER SELECTOR SWITCH
Used to check each phase for load condition.
NOTE: Always leave this switch in the ON position
while the unit is running.
10. A.C. AMMETER
Shows the generator load on each phase. The phase is
selected with the Ammeter Selector switch
(
Item 9
)
.
Summary of Contents for NL673L
Page 11: ...ONL673L 7 13 9 Notes...