Northern Industrial 15763 Owner'S Manual Download Page 5

Page: 5 of 8 

·

  Set the air pressure on your compressor to 90 PSI. Do not exceed the recommended air 

pressure of 90 PSI. 

·

  Check the air connection for leaks. 

·

  Turn off the compressor and disconnect the air source hose in preparation to load bits into 

the Air Needle Scaler. 

·

  Take out the needle scaler from the box (See Fig. 2), screw it into the cylinder (See Fig. 3), 

tighten it (See Fig. 4) and start the trigger. 

   

   

 

Fig. 2                                                    Fig. 3                                        Fig. 4 

·

  Gently squeeze the trigger and move slowly along the workpiece. Do not push down on the 

scaler; let it do the work. If it does not do the intended job to satisfaction, examine your scaler 
to see if it is worn or dull. 

·

  When  you  are  finished,  turn  off  the  air  supply  and  then  hold  the  Air  Needle  Scaler  a  safe 

distance away from yourself and others and squeeze the trigger to bleed off the remaining air. 
Then, disconnect the air hose. 

 

MAINTENANCE 

WARNING: 

Make sure this tool is disconnected from its power source before attempting 

any maintenance, cleaning, or inspection. 

·

 

Maintain your tools. 

It is recommended that the general condition of any tool be examined 

before it is used. Keep your tools in good repair by adopting a program of conscientious repair 
and maintenance in accordance with the recommended procedures found in this manual. If any 
abnormal vibrations or noise occurs, turn the tool off immediately and have the problem 
corrected before further use. Have necessary repairs made by qualified service personnel.

 

·

 

Cleaning.

 

Use only soap and a damp cloth to clean your tools. Many household cleaners are 

harmful to plastics and other insulation. Never let liquid get inside a tool.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for 15763

Page 1: ...edle Scaler OWNER S MANUAL WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal...

Page 2: ...ions Specifications Blows per minute 4500 Max air pressure 90 PSI Air Consumption 5 CFM Air Inlet Diameter 1 4 Accessories 19 needle attachments Needles 7 L x 1 8 Thick GENERAL SAFETY RULES WARNING Re...

Page 3: ...event of a power failure while a tool is being used turn the switch off to prevent surprise starting when power is restored Do not overreach Keep proper footing and balance at all times Remove adjust...

Page 4: ...make sure that the gloves do not interfere with operating the trigger Test your gloves with the trigger before attaching the unit to an air source Never start the tool unless you have a firm grip with...

Page 5: ...Needle Scaler a safe distance away from yourself and others and squeeze the trigger to bleed off the remaining air Then disconnect the air hose MAINTENANCE WARNING Make sure this tool is disconnected...

Page 6: ...Item Description Qty 1 H 1 Handle 1 10 H 10 Throttle Spring 1 2 H 2 Pin 2 11 H 11 Hose Adapter 1 3 H 3 Ball Seat 1 12 H 12 Upper Valve Case 1 4 H 4 O ring 1 13 H 13 Valve Disc 1 5 H 5 Regulator 1 14...

Page 7: ...Fig 6 Parts List for the Needle Scaler Part Item Description Qty 1 N 1 O ring 2 2 N 2 Fix Nut 1 3 N 3 Drive 1 4 N 4 Body 1 5 N 5 Screw 3 6 N 6 Needle fixer 1 7 N 7 Needle 19 8 N 8 Spring 1 9 N 9 Bear...

Page 8: ...ica from bricks and cement and other masonry products and arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To r...

Reviews: