5

General Overview

To compress air, the piston moves up and down in

the cylinder. On the down stroke air is drawn in

through the valve inlet. The discharge valve remains

closed. On the upstroke of the piston air is

compressed. The inlet valve closes and air is forced

out through the discharge valve, through the check

valve, and into the air tank. Working air is not

available until the compressor has raised the tank

pressure above that required at the air service

connection. The air inlet filter openings must be

kept clear of obstructions, which could reduce air

delivery of the compressor.

Installation and Location

Locate the compressor in a clean, dry and well

ventilated area. The compressor should be located

12 to 18 inches from walls or any other obstruction

which would interfere with airflow. Place the

compressor on a firm, level surface. The

compressor is designed with heat dissipation fins

which allow for proper cooling. Keep the fins (and

all other parts which collect dust or dirt) clean. A

clean compressor runs cooler and provides longer

service. Do not place rags, containers or other

material on top of the compressor.

Connecting to Power Source

This air compressor is designed to operate on a

properly grounded 120 volt, 60Hz, single phase,

alternating current (ac) power source with a fused

20 amp time delayed fuse or circuit breaker. It is

recommended that a qualified electrician verify the

ACTUAL VOLTAGE at the receptacle into which the

unit will be plugged and confirm that the receptacle

is properly fused and grounded. The use of the

proper circuit size can eliminate nuisance circuit

breaker tripping while operating your air compressor.

Extension Cords

For optimum Air Compressor performance an

extension cord should not be used unless

absolutely necessary. If necessary, care must be

taken in selecting an extension cord appropriate for

use with your specific Air Compressor. Select a

properly grounded extension cord which will mate

directly with the power source receptacle and the

Air Compressor power cord without the use of

adapters. Make certain that the extension cord is

properly wired and in good electrical condition.

Maximum length of extension cord should be 50

feet. Minimum wire size of extension cord should be

12 gauge.

Attaching an Air Hose

Your Air Compressor is supplied with a 1/4" Quick

Disconnect Air Chuck. Once you have correctly

installed the Air Chuck (See Installing the Air Chuck

on p.4) your compressor will be ready to accept air

hoses equipped with 1/4" male air couplers.

Note:

Use only air hoses rated for use with 115psi

air pressure or higher.

To install an air hose, equipped with a 1/4" male

coupler:

1. Pull back on Air Chuck outer sleeve to allow

coupler to be fully inserted into Air Chuck.

2. Insert coupler into Air Chuck.

3. Release outer sleeve of Air Chuck.

4. Verify that air hose is securely connected to Air

Chuck by pulling lightly on air hose.

(See Figure 5)

Adjusting the Air Pressure

Your Air Compressor is supplied with an Air

Pressure Regulator. This Regulator adjusts the air

pressure.

To increase air pressure, turn Air Regulator

clockwise.

To decrease air pressure, turn Air Regulator

counterclockwise.

(See Figure 6)

Cold Weather Starting

Temperatures below freezing (32°F) cause the

metal parts of your Air Compressor to contract and

that makes starting more difficult. To assist the Air

Compressor in starting in cold weather, follow

Figure 5.

Attaching an Air Hose

Figure 6.

Adjusting the Air Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 123008

Page 1: ...COMPRESSOR OWNER S MANUAL Item 123008 WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in seriou...

Page 2: ...cussed in this instruction manual cannot cover all possible conditions or situations that could occur It must be understood by the operator that common sense and caution are factors which cannot be bu...

Page 3: ...ly 14 Do not force tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it was designed 15 Do not use the tool if the switch does not...

Page 4: ...power supply Pressure Gauges These dual gauges indicate the amount of air pressure built up in the air tank as well as the air pressure being delivered to the air chuck Safety Valve The Safety Valve d...

Page 5: ...4 Note DO NOT over tighten Air Filter OPERATION BEFORE OPERATING YOUR NEW AIR COMPRESSOR please check the following points carefully 1 Check that all nuts and bolts are secure 2 Make sure oil has been...

Page 6: ...perating your air compressor Extension Cords For optimum Air Compressor performance an extension cord should not be used unless absolutely necessary If necessary care must be taken in selecting an ext...

Page 7: ...Oil Sight Glass 3 Replace Oil Breather Cap before starting compressor Changing the Air Compressor Oil Note This compressor uses only SAE 5W 30 motor oil 1 Remove the Drain Plug under the Oil Sight Gl...

Page 8: ...7...

Page 9: ...28 Screw M8x20 29 Connecting Rod 30 Piston 31 Spring Washer 32 Piston Pin 33 Cylinder Gasket 34 Cylinder 35 Spring Washer 6 36 Washer 6 37 Screw M6x40 38 Gasket 39 Sealer Ring 40 Valve Gasket 41 Valv...

Page 10: ......

Reviews: