North Star 5500 BDG Owner'S Manual Download Page 4

3

                     

MACHINE COMPONENT IDENTIFICATION

      

                                                                          Figure 1  

(Ref. 1-4) 

00041

Ref.

Description

Ref.

Description

1

Circuit Breakers

5

7/8” shaft

2

120V 20A Duplex Receptacle

6

Mounting feet

3

240V 20A Locking Receptacle

7

Fan vents

4

Grounding screw

Figure 2  

(Ref. 5-7)

00042

Summary of Contents for 5500 BDG

Page 1: ...P r o v e n P e r f o r m a n c e MODEL 5500 BDG ITEM 165913 Belt Driven Generator M165913B OWNER S MANUAL Any Questions Comments or Problems Call Customer Service at 1 800 270 0810...

Page 2: ...Generator IMPORTANT If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in the safe and proper operation of this machine Reads and un...

Page 3: ...uency 59 0 62 0 Hertz Hz Power Factor 100 Engine 11 hp max 9 hp recommended Engine Speed 3540 3720 RPM 120 V Receptacle 20 Amp A duplex NEMA 5 20R 240 V Receptacle 20 Amp A Locking Device NEMA L6 20R...

Page 4: ...TIFICATION Figure 1 Ref 1 4 00041 Ref Description Ref Description 1 Circuit Breakers 5 7 8 shaft 2 120V 20A Duplex Receptacle 6 Mounting feet 3 240V 20A Locking Receptacle 7 Fan vents 4 Grounding scre...

Page 5: ...ment from original design and manufacture Before using the user shall determine the suitability of this product for its intended use and assumes liability therein ANSI SAFETY DEFINITIONS DANGER indica...

Page 6: ...correct diameter sheave Note that a notched V belt requires only one sheave while the standard V belt requires 2 side by side sheaves and 2 V belts All V belts have a B size cross section Figure 3 000...

Page 7: ...e 2 to 4 times as much current to start than to run Repulsion Induction motors are the easiest to start and require 1 5 to 2 5 times as much to start than to run Most fractional motors take about the...

Page 8: ...inutes to restart due to its normal build up of compressor head pressure NOTE For extremely hard to start loads such as air conditioners and air compressors consult the equipment dealer to determine t...

Page 9: ...nding Frequent operation of the engine generator will also ensure that the set is operating properly should it be needed in an emergency Generator Maintenance The generator head is brushless and maint...

Page 10: ...ting a Generator is overloaded b Insufficient ventilation a Reduce the load See Load Application section of this manual b Make sure there is at least 3 feet of clearance on all sides of generator No o...