Problem

Possible Causes

Possible Remedies

Voltage too low.

a)   Engine speed too slow.

b)   Generator is overloaded.

a)   Increase tractor RPMs.
b)   Reduce the load. (See Load
Application section of this manual.)

Circuit breaker trips.

a)   Defective load connected to generator.
b)   Defective receptacle.
c)   Generator overloaded.

d)  Defective circuit breaker.

a)   Disconnect load.
b)   Replace receptacle.
c)   Reduce the load. (See Load
Application section of this manual.)
d)   Contact Customer Service for the
nearest service center.

Voltage too high.

a)   Engine speed too high.

a)   Contact Customer Service for the
nearest service center.

Generator overheating.

a)   Generator is overloaded.

b)   Insufficient ventilation.

a)   Reduce the load. (See Load
Application section of this manual.)
b)   Make sure there is at least 3 feet of
clearance on all sides of generator.

No output voltage.

a)   Defective load connected to generator.
b)   Broken or loose wire.

c)   Defective receptacle.
d)   Defective stator.

e)   Defective rotor.

f)   Defective capacitor.

g)  Defective circuit breaker.

h)   Engine speed too slow.
I)    PTO not engaged.
j)    Gear box is malfunctioning.

a)   Disconnect load.
b)   Replace wire.
c)   Replace receptacle.
d)   Contact Customer Service for the
nearest service center.
e)   Contact Customer Service for the
nearest service center.
f)   Contact Customer Service for the
nearest service center.
g)   Contact Customer Service for the
nearest service center.
h)   Increase tractor RPMs.
I)    Engage PTO.
j)    Contact Customer Service for the
nearest service center.

Excessive gear box
noise.

a)   Defective bearing.

b)   Defective gear.

c)   No or low gear oil.
d)   PTO driveline is operating at an angle of
greater than 15

°

.

e)   Unsynchronized PTO driveline.

a)   Contact Customer Service for the
nearest service center.
b)   Contact Customer Service for the
nearest service center.
c)   Fill gear box to oil level sight.
d)   Reposition the tractor or generator so
the angle is  reduced  to less  than 15

°

 both

vertically and  horizontally.
e)   Disassemble PTO driveline and
reassemble with CV joints synchronized.

Summary of Contents for 165937

Page 1: ...MODEL 27500 PTOG ITEM 165937 Power Take Off Generator M165937D OWNER S MANUAL Any Questions Comments or Problems Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 30 AM to 5 30 PM Saturda...

Page 2: ...If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in safe and proper operation of this machine Reads and understands the manuals per...

Page 3: ...gnetic Gear Box Gear Ratio 1 7 Gear Oil SAE 80W 90 Oil Capacity 53 Qt 5 L Dimensions Length 36 95 93 9 cm Width 16 85 42 8 cm Height 20 79 52 8 cm Gross Weight 425 lb 193 2 kg ANSI SAFETY DEFINITIONS...

Page 4: ...Clamp 6 Fan Vents 16 100A Circuit Breaker 7 Mounting Holes 17 120 240V 100A Pin and Sleeve 8 120V 30A Twistlock Receptacle 18 60A Circuit Breaker 9 120V 20A Duplex Receptacles 19 Shield 10 20A Circuit...

Page 5: ...One 60A thermal magnetic breaker References 11 Shield Plastic implement shield NEVER operate generator without shield in place INTRODUCTION Before attempting to mount your generator thoroughly study...

Page 6: ...minimize the angle of the driveline 15 maximum The smaller the angle of operation the longer the driveline will last When trailer mounting the generator select a trailer that is wide enough to withsta...

Page 7: ...Hp motor Running Watts RI type Cap type SP type 1 6 525 7 11 9 18 16 22 1 4 700 9 15 12 23 22 32 1 3 875 11 18 14 29 26 35 1 2 1175 15 25 20 40 NA 1 1925 24 40 32 64 NA 1 1 2 2400 30 50 40 80 NA 2 29...

Page 8: ...t 1 800 270 0810 GROUNDING All units must be grounded Drive a 3 4 or 1 copper pipe or rod into the ground close to the generator The pipe rod must penetrate moist earth Connect an approved ground clam...

Page 9: ...rmed only by a qualified electrical service technician USE ONLY NorthStar APPROVED REPAIR PARTS AVAILABLE AT 1 800 270 0810 A Bearing The bearings used in this generator are a heavy duty sealed ball b...

Page 10: ...n or loose wire c Defective receptacle d Defective stator e Defective rotor f Defective capacitor g Defective circuit breaker h Engine speed too slow I PTO not engaged j Gear box is malfunctioning a D...

Reviews: