North Star 165920 Owner'S Manual Download Page 43

Limited Warranty 

 

                      

43

 

                          

 

 

Dear Valued Customer: 
 
The NorthStar Product you just purchased is built with the finest material and craftsmanship.  Use this product 
properly and enjoy the benefits from its high performance.  By purchasing a NorthStar product, you show a 
desire for quality and durability. 
 
Like all mechanical equipment this unit requires a due amount of care.  Treat this unit like the high quality 
piece of machinery it is.  Neglect and improper handling may impair its performance.  Please thoroughly read 
the instructions and understand the operation before using your product. 

 

Limited Warranty 

 

NorthStar shall warranty any

 

piece of equipment manufactured, or parts of equipment manufactured, to be free 

from defects in material or workmanship for a period of 2 years from the date of purchase by user. This 
warranty applies to the original purchaser of the equipment and is non transferable. Verification of purchase is 
the responsibility of the buyer. Parts will be replaced or repaired at no charge, except when the equipment has 
failed due to lack of proper maintenance. Any misuse, abuse, alteration or improper installation or operations 
will void warranty. Determining whether a part is to be replaced or repaired is the sole decision of NorthStar. 

 
NOTE: 

Some services performed by parties other than NorthStar may void warranty. 

 
This warranty covers parts only. It will not provide for replacement of complete products due to defective parts. 
Components not manufactured by NorthStar such as engines are guaranteed by their manufacturer and can be 
serviced at factory-authorized locations near you. Any costs incurred due to replacement or repair of items 
outside of a NorthStar approved facility is the responsibility of the buyer and not covered under warranty. 
NorthStar can supply you with the service center location in your area. 
 
This warranty specifically excludes the following; failure of parts due to damage caused by accident, fire, 
flood, windstorm, acts of God, applications not approved by NorthStar in writing, corrosion caused by 
chemicals, use of replacement parts which do not conform to manufacturer’s specifications, and damage caused 
by vandalism. Additional exclusions: loss of running time, inconvenience, loss of income, or loss of use, 
including any implied warranty of merchantability of fitness for a specific use. 
 
Warranty does not cover items subject to normal wear such as tires, receptacles or any part subject to direct 
physical contact by the public. This warranty does not cover any personal injury or damage to surrounding 
property caused by failure of any part.  
 
This warranty is in lieu of any other warranty expressed or implied and NorthStar assumes no other 
responsibility or liability outside that expressed within this warranty. 
 
 
Please fill in the following information and have it on hand when you call in a warranty claim. 
 
Customer Number: ______________________________________________________________ 
 
Date of Purchase: _______________________________________________________________ 
 
NorthStar Serial Number: _________________________________________________________ 
 
Item Number: __________________________________________________________________ 
 

 

Summary of Contents for 165920

Page 1: ...nsion cords of proper size NEVER plug the generator directly into a wall outlet ANY connection to a building s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY POWER via a UL approved transfe...

Page 2: ...Hazard Signal Word Definitions 2...

Page 3: ...NG BACK UP Power Source 13 4 Selecting a Suitable Site 16 5 Grounding the Generator 18 6 Battery Installation 19 Operation 1 General Safety Rules for Operation 20 2 Preparing for Operation 23 3 Starti...

Page 4: ...ectrical devices and may also result in fire Be sure to read about site selection and grounding requirements for running this generator More detailed information can be found in the Installation Initi...

Page 5: ...questions about the appropriate use of this generator Warranty Registration Please fill out and submit the warranty registration card so that we have your contact information for any future product l...

Page 6: ...Start Recoil 120 V Receptacle 2 20 Amp A duplex GFCI NEMA 5 20R 1 30 Amp A locking device 2 NEMA L5 30R 1 50 Amp A straight blade NEMA 5 50R 120 240 V Receptacle 30 Amp A locking device NEMA L14 30R...

Page 7: ...tery acid contacts eyes skin or clothing CONNECT cables in correct sequence FIRST RED to POSITIVE terminal then BLACK to NEGATIVE terminal When disconnecting DISCONNECT BLACK cable first then RED NEVE...

Page 8: ...lon Gas Tank 3 Full Power Switch 13 Super Silent Muffler 4 Voltmeter 14 Generator Head 5 Idle Control On Off Switch 15 Battery Box 6 Hour Meter 16 Vibration Isolation Mount 7 Main Line Circuit Breaker...

Page 9: ...er Reference 9 30A Circuit Breaker 30 amp A push to reset circuit breaker Reference 10 20A Circuit Breaker 20 amp A push to reset circuit breaker Reference 11 Gas Cap with Gauge The gas cap is extra l...

Page 10: ...te If wattage is not given on the device s nameplate the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage Watts Volts X Amps Example conversion to watts 120 Volts X...

Page 11: ...g at the same time with the generator 2 List the greater of the running or starting wattage next to each device as obtained from the devices nameplate or Table 1 If only the running wattage for a devi...

Page 12: ...n electric start models only Each of these steps is discussed in detail below 1 Unpacking Delivery Inspection You should inspect the generator immediately after you receive delivery See the Machine Co...

Page 13: ...r building s electrical system by isolating your generator from your utility company s power lines AND b Connects your generator to a critical subset of your building s circuits that are needed for em...

Page 14: ...NEMA 5 50P mating plug 2 One 120 240 Volt 30 Amp locking receptacle NEMA L14 30R locking receptacle compatible with L14 30P mating plug 3 One 120 Volt 30 Amp locking receptacle NEMA L5 30R receptacle...

Page 15: ...the length of the cord Table 2 WARNING Use of under sized extension cords can cause electric shock fire or damage to connected devices All extension and appliance cords must be in good condition and...

Page 16: ...r propane as the fuel source to power the generator Follow the directions below for choosing a location to operate your generator in order to avoid carbon monoxide poisoning The location you choose to...

Page 17: ...at least 7 from exhaust and allow for adequate clearance above generator so that heat does not build up Hot exhaust clearance The exhaust gas from your generator is extremely hot and can cause combus...

Page 18: ...cian 2 Connect an approved ground clamp to the pipe 3 Run a 10 gauge wire from the clamp to the generator grounding post located on the rear of the generator head 4 Do not connect the generator ground...

Page 19: ...nt any sparking that could lead to an explosion ALWAYS follow the general battery safety rules and instructions listed below General Battery Safety Rules ALWAYS use eye protection when handling batter...

Page 20: ...adults should set up and operate the generator Do not let children operate Intended use Carefully read about and understand the intended use of this generator Do not use for other purposes as unforese...

Page 21: ...ate of California to cause cancer birth defects or other reproductive harm Avoid inhalation of exhaust Wet conditions Do not operate the generator or handle any electrical equipment while standing in...

Page 22: ...d retain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or plastic...

Page 23: ...ake sure that any regular maintenance has been performed as prescribed in this manual in the Maintenance Repair section 1 Refer to the engine owner s manual for engine maintenance instructions 2 Make...

Page 24: ...allow to cool for at least two minutes before removing gas cap Note A running or still hot engine is hot enough to ignite fuel 3 Remove generator gasoline cap 4 Add gasoline through the fill opening...

Page 25: ...A tank of gasoline should last about 4 hours under 100 load and about 8 hours under 50 load Inspect Fuel System Check for Leaks Inspect fuel system check for leaks BEFORE starting generator Do not sta...

Page 26: ...en the engine starts b Using recoil start i Turn the engine key switch to the ON position ii Pull the starter grip lightly until you feel resistance then pull the starter cord out briskly and rapidly...

Page 27: ...The voltmeter s needle should be within the green area initially and during all load conditions 4 If measured voltage is not within the specified range have generator adjusted by factory authorized pe...

Page 28: ...t The recommended sequence is as follows a Connect items with motors such as refrigerators freezers air conditioners or small hand tools one at a time Let each motor stabilize before connecting the ne...

Page 29: ...k is empty Residual fuel in the tank could ignite o Away from extreme high or low temperatures Note Do not store with battery charger always connected Batteries that are over charged can boil themselv...

Page 30: ...ding fuel stabilizer to the gasoline following manufacturer s instructions Fuel stabilizer steps 1 Ensure gasoline tank is full 2 Add fuel stabilizer to fuel tank 3 Run engine at least 10 minutes afte...

Page 31: ...ite terminals of the capacitor together with the tip of the screwdriver If there is stored charge in the capacitor a spark will be generated thereby discharging the capacitor Replace guards Make sure...

Page 32: ...the Specifications section If the engine is equipped with a spark arrester muffler clean and inspect it regularly follow manufacturer s service instructions Replace if damaged Keep generator clean Kee...

Page 33: ...load connected to generator b Broken or loose wire c Defective receptacle d Defective stator e Defective rotor f Defective capacitor g Circuit breaker tripped a Disconnect load b Bring generator to a...

Page 34: ...will also void the warranty Engine speed Never attempt to modify the engine speed setting The engine speed is preset at 3600 RPM for safe and optimal performance of the generator If speed needs adjust...

Page 35: ...al codes If the generator is not isolated from the utility power system by such means generator output will back feed into the utility power grid This may result in injury or death to utility power wo...

Page 36: ...r exhaust dangers This product contains or emits chemicals known to the State of California to cause cancer birth defects or other reproductive harm Avoid inhalation of exhaust Smoking sparks Never sm...

Page 37: ...rder to ensure that generator cannot be started in a storage location or by untrained persons Storage location Store the generator in a dry location away from sources of heat open flames sparks or pil...

Page 38: ...Exploded View Rev S 38...

Page 39: ...2 Battery Box 1 16 34172 Isolation Mount 4 17 32844 Lower Bracket 4 18 778483 Generator Base 1 19 82018 5 16 18 x 2 Screw 4 20 779423 Decal 1 21 777108 Battery Cable Negative 1 22 777164 Battery Cable...

Page 40: ...Wiring Diagram Rev S 40...

Page 41: ...240 Volt Full Power Switch 1 18 32805 Hour Meter 1 19 38223 Panel Face Plate 1 20 31005 Circuit Breaker 30 Amp 120 240 Volt 1 21 31118 Thermal Circuit Breaker 50 Amp 120 Volt 1 25 38647 Connector Wir...

Page 42: ...7 Fan 1 4 779920 Drive End Bracket 1 5 779786 Enclosing Band 1 6 777304 End Cover 1 7 38271 End Cover Plug 1 8 779787 Stator 1 9 779788 Rotor 1 10 307481 Varistor 2 11 779789 Diode 2 12 779790 Securin...

Page 43: ...h as engines are guaranteed by their manufacturer and can be serviced at factory authorized locations near you Any costs incurred due to replacement or repair of items outside of a NorthStar approved...

Page 44: ...44 Manufactured by Northern Tool Equipment Co 2800 SouthCross Drive West P O Box 1499 Burnsville MN 55337 0499...

Reviews: