MODEL 2900 BDG,

 

ITEM # 165915

Belt  Driven  Generator
  

     

M165915A

OWNER’S MANUAL

                                                                               00035

2900 BDG

                      Questions or comments?  Call 1-800-270-0810

Summary of Contents for 165915

Page 1: ...P r o v e n P e r f o r m a n c e MODEL 2900 BDG ITEM 165915 Belt Driven Generator M165915A OWNER S MANUAL 00035 2900 BDG Questions or comments Call 1 800 270 0810...

Page 2: ...en Generator IMPORTANT If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in safe and proper operation of this machine Reads and unde...

Page 3: ...wire Frequency 59 0 62 0 Hertz Hz Power Factor 100 Engine 5 hp recommended Engine Speed 3540 3720 RPM 120 V Receptacle 15 Amp A duplex NEMA 5 15R 240 V Receptacle 15 Amp A duplex NEMA 6 15R Circuit B...

Page 4: ...TIFICATION Figure 1 Ref 1 4 00036 Ref Description Ref Description 1 Circuit Breakers 5 7 8 shaft 2 120V 15A Duplex Receptacle 6 Mounting feet 3 240V 15A Duplex Receptacle 7 Fan vents 4 Grounding screw...

Page 5: ...ability of this product for its intended use and assumes liability therein ANSI SAFETY DEFINITIONS DANGER indicates an imminently hazardous situation which if not avoided will result in death or serio...

Page 6: ...ss section The shaft speed of the generator must be between 3540 3720 RPM At no load the correct speed is 3720 RPM If the engine is a 3600 RPM engine than a sheave diameter ratio of 1 1 should be used...

Page 7: ...fractional motors take about the same amount of current to run them whether they are of Repulsion Induction RI Capacitor Cap or Split Phase SP type The following chart shows the approximate current r...

Page 8: ...For extremely hard to start loads such as air conditioners and air compressors consult the equipment dealer to determine the maximum wattage PRE START PREPARATIONS Your generator has been thoroughly...

Page 9: ...e set is operating properly should it be needed in an emergency Generator Maintenance The generator head is brushless and maintenance free Any major generator service including the installation or rep...

Page 10: ...ting a Generator is overloaded b Insufficient ventilation a Reduce the load See Load Application section of this manual b Make sure there is at least 3 feet of clearance on all sides of generator No o...