SPECIFICATIONS

Item Number

#165929

Maximum Output

13000 Watts (W)

Continuous Output

12000 Watts (W)

Voltage

120 / 240 Volt (V)

Phase

Single phase (4-wire)

Frequency

59.0-63.0 Hertz (Hz)

Power Factor

100 %

Minimum PTO HP

24 HP at 540 RPM

Input Shaft

1 3/8” Diameter, 6 spline

120V Receptacle

(2) 20 Amp (A) duplex (NEMA 5-20R)
30 Amp (A) twistlock (NEMA L5-30R)

120/240V Receptacle

50 Amp (A) Straight blade (NEMA 14-50R)

Circuit Breaker

(2) 20 Amp (A) thermal, push to reset style

30 Amp (A) thermal, push to reset style

(2) 40 Amp (A) thermal, push to reset style

Gear Box
     Gear Ratio

1:7

     Gear Oil

SAE 80W-90

     Oil Capacity

.86 Qt. (.82 L)

Dimensions
     Length

28.38” (72.1 cm)

     Width

14.25” (36.2 cm)

     Height

12.50” (31.1 cm)

Gross Weight

127 lb. (57.7kg)

   ANSI SAFETY DEFINITIONS

DANGER

 indicates an imminently hazardous situation  which,  if  not  avoided,

will result in death or serious injury.  This signal word is to be limited to the
most extreme situations.

WARNING

 indicates a potentially hazardous situation which, if not avoided,

could result in a death or

 

serious injury.

CAUTION

 indicates a potentially hazardous situation, which if not avoided,

may result in minor or moderate injury.  It may also be used to alert against
unsafe practices.

Summary of Contents for 13000 PTOG

Page 1: ...DEL 13000 PTOG ITEM 165929 Power Take Off Generator M165929A OWNER S MANUAL 13000 PTOG Any Questions Comments or Problems Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 30 AM to 5 30 PM...

Page 2: ...Generator IMPORTANT If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in safe and proper operation of this machine Reads and underst...

Page 3: ...40 Amp A thermal push to reset style Gear Box Gear Ratio 1 7 Gear Oil SAE 80W 90 Oil Capacity 86 Qt 82 L Dimensions Length 28 38 72 1 cm Width 14 25 36 2 cm Height 12 50 31 1 cm Gross Weight 127 lb 57...

Page 4: ...0A Circuit Breaker 11 Shield 3 20A Circuit Breakers 12 Gear Box 4 Warning Decals 13 Grounding Screw 5 1 3 8 6 Spline Input Shaft 14 Mounting Holes 6 Oil Drain Plug 15 Fan Vents 7 Voltmeter 16 Oil Leve...

Page 5: ...EMA plug number L5 30P which is supplied with the generator Reference 10 120 240V Receptacle This straight blade receptacle is 120 240V 50A This receptacle accepts a NEMA plug number 14 50P ALWAYS use...

Page 6: ...r highly electrical conductive areas and on construction job sites to prevent electric shock ALWAYS remove PTO driveline before working on the generator ALWAYS provide adequate ventilation Do not oper...

Page 7: ...oncrete After the the generator is firmly mounted attach the PTO driveline to the generator then the tractor Use a synchronized PTO driveline rated at 24 HP minimum DANGER Always have proper guarding...

Page 8: ...tors particularly low cost split phase motors are very hard to start and require 5 to 7 times more current to start than to run Capacitor motors are easier to start and usually require 2 to 4 times as...

Page 9: ...Compressor 1 2 HP 1400 a Curling Iron 700 Dishwasher 1200 Edge Trimmer 500 Electric Nail Gun 1200 Electric Range one element 1500 Electric Skillet 1250 Freezer 800 b Furnace Fan 1 3 HP 1200 a Hair Dry...

Page 10: ...ch or a stop watch the clock should be correct within 2 seconds per minute All speed setting adjustments should be done by a qualified technician GENERATOR CARE The generator head is a two pole 3600 R...

Page 11: ...loose wire c Defective receptacle d Defective stator e Defective rotor f Defective capacitor g Defective circuit breaker h Engine speed too slow I PTO not engaged j Gear box is malfunctioning a Disco...