or valves.  If the unit leaks and water enters the insulation in the tank, 

the thermal efficiency will be dramatically reduced.

Vacuum tubes need to be properly inserted so they  are sealed and not 

leaking any water.

If a vacuum tube appears milky white, it signifies the tube has a crack 

and needs replacing. This will only happen through misuse or by ac-

cidently damaging the tube. Once installed correctly the tubes will not 

leak.

Filling the tank

IMPORTANT!

If not in the shade, ALWAYS make sure the tubes are covered with a 

white sheet or similar prior to filling the tank.

If the tubes heat up prior to filling, there is a chance of one or more of 

them cracking or exploding.

Filling two hours after sunset or before sunrise is the safest time.

REMEMBER internal tube temperatures in direct sunlight can reach 250 

oC.

Tube maintanace

The vacuum tubes need minimal maintanance, however their efficiency 

can decrease if they are covered by dirt or dust. It is recommended you 

keep the tubes clean by washing them with a dishwashing liquid or soap 

if they have been affected by seasonal conditions.

Water quality

Rain water

Clean rain water is highly recommended to fill and top up the main 

tank.

Summary of Contents for NS-200WB

Page 1: ...NS 200WB NS 300WB Evacuated Tube Solar Hot Water System Operating Manual...

Page 2: ...ling The information in this manual includes technical data maintanance problem solving and precautions As our products are continually being improved there may be some dif ferences between images and...

Page 3: ...200 NS 300 1 Outer tank 2 Heat Insulation Layer 3 Inner tank 4 Wetback input output 5 Water tank 6 Water Inlet outlet 7 Heating element input 8 Vacuum tubes 9 Frame 10 O ring Seal 11 End Bar 12 Plasti...

Page 4: ...rial Stainless steel plate Certification Watermark AS 3498 2009 Material Stainless steel Aluminium Copper Glass Borax MAIN TANK Thickness of the stainless steel SS 0 4mm Quality of SS food grade 304 2...

Page 5: ...ving parts B Hail wind and frost resistant C Tri fire special high temperature tube with high infra red absorbtion rate D Polyurethane foam to reduce the heat loss heat preservation time is at least 4...

Page 6: ...re all vents are not obstructed As this is not a pressurised tank it is important the exhaust is allowed to breathe If blocked the tank will expand and contract with the heat produced by the water and...

Page 7: ...towards the tank When vacuum tubes are empty and hvae been exposed to the sun the interior temperature may reach above 250 C DO NOT fill the tank if the tubes have been exposed to direct sun for any...

Page 8: ...N rth Solar Solar Hot Water Solutions Installation of multiple units Isolation valve Header tank Vent Heat exchange coil Hot Cold tap Tempering valve Isolation valve Header tank Vent Heat exchange coi...

Page 9: ...ant to use appropriate piping to cope with high temperature and pressure refer to your Registered plumber for local regulations Copper piping is ideal due to its strength non odour heat resistance and...

Page 10: ...ot in the shade ALWAYS make sure the tubes are covered with a white sheet or similar prior to filling the tank If the tubes heat up prior to filling there is a chance of one or more of them cracking o...

Page 11: ...anode rods to absorb Anode rods are designed to attract corrosive elements in the water thereby diminishing corrosion ANODE RODS North Solar sells high quality anode rods and highly recommends in sta...

Page 12: ...g tank with float valve 2 All parts composed of stainless steel and brass 3 Cold and hot water pipes are separated avoiding scale build up and damging the float valve improving lifespan of the unit 4...

Page 13: ...northsolar com au 0435 016 869 N rth Solar Solar Hot Water Solutions...

Reviews: