Freeze Owner’s Manual
6
|
Page
www.northslopechillers.com | (866) 826-2993 | 3130 S 1030 W, Suite 1 | Salt Lake City, UT 84119
Revised: 12/18/2020
NSC5000 and NSC10000 Models
FRONT (NSC5000 and NSC10000 models)
BACK (NSC5000 and NSC10000 models)
Page 1: ...Freeze Owner s Manual 1 Page www northslopechillers com 866 826 2993 3130 S 1030 W Suite 1 Salt Lake City UT 84119 Revised 12 18 2020...
Page 2: ...ations 3 Cautions Warnings 3 Specification sheet 4 Chiller Component Overview 5 Installation 8 User Interface 9 Modifying Parameters 9 Display Unit 9 Thermostat Differential 9 Upper and Lower limit of...
Page 3: ...ltage outside of these ranges will damage the compressor i 110V model will operate on voltages between 100 130V ii 230V model will operate on voltages between 200 250V iii 460V model will operate on v...
Page 4: ...2 W x 32 H 34 L x 28 W x 39 H 34 L x 43 W x 40 H Model NSC5000 460 3 NSC5000 LT 460 3 NSC10000 460 3 NSC1000 LT 460 3 Voltage 460 3 Phase Compressor Power 5 HP 10 HP Cooling Capacity BTU hr 60 000 BTU...
Page 5: ...slopechillers com 866 826 2993 3130 S 1030 W Suite 1 Salt Lake City UT 84119 Revised 12 18 2020 Chiller Component Overview NSC0500 NSC1000 and NSC2000 Models FRONT NSC0500 NSC1000 and NSC2000 models B...
Page 6: ...Manual 6 Page www northslopechillers com 866 826 2993 3130 S 1030 W Suite 1 Salt Lake City UT 84119 Revised 12 18 2020 NSC5000 and NSC10000 Models FRONT NSC5000 and NSC10000 models BACK NSC5000 and N...
Page 7: ...Owner s Manual 7 Page www northslopechillers com 866 826 2993 3130 S 1030 W Suite 1 Salt Lake City UT 84119 Revised 12 18 2020 Fluid Circuit NSC5000 and NSC10000 models Electrical NSC5000 and NSC10000...
Page 8: ...nit on a flat level surface in a well ventilated area 2 Connect inlet and outlet fluid hoses Confirm hoses are connected to proper inlet and outlet ports 3 Fill the reservoir 4 Connect to power Ensure...
Page 9: ...display automatically reverts to showing the current temperature Or Press 2 x Back Modifying Parameters Display Unit Default Unit Fahrenheit F Adjust display unit first before changing other paramete...
Page 10: ...ess OK Upper and Lower limit of Thermostat Set Point Default Limits Upper 65 F Lower 25 F 1 Press up and down and hold 5 seconds to access the menu 2 Press up down to find 3 Press OK 4 Press up down t...
Page 11: ...lve not working Compressor starts but trips on overload protector 1 Suction or discharge pressure is too high 2 Low line voltage 3 Broken overload protector 4 Mechanical damage to compressor 5 Shorted...
Page 12: ...too low 2 Excessive refrigerant 3 Broke oil pump Fluid temperature too cold 1 Set point temperature is too low 2 Malfunctioning temperature controller 3 Malfunctioning temperature sensor 4 Leaking re...
Page 13: ...URPOSE OR USE OTHER THAN THE LIMITED WARRANTY SET FORTH ABOVE 2 LIMITATION OF LIABILITY MANUFACTURER S SOLE LIABILITY SHALL BE AS SET FORTH HEREIN AND SHALL EXTEND ONLY TO INSPECTION REPLACEMENT OR RE...
Page 14: ...plicable pre judgment and post judgment interest if any awards losses damages costs penalties expenses claims and liabilities including reasonable attorneys fees witness fees and court costs and any o...