Nortel Station Port Adapter DS30 Installation Manual Download Page 2

1

DS30/Station Port Adapter

Installation Guide

DS30/STATION PORT ADAPTER

REGULATORY APPROVAL

Table 1.  Regulatory Approvals

TYPE

COUNTRY

SPECIFICATION

PROCEDURE

Radiated

Canada

ICES-003/CISPR22 Class B

ANSI C63.4

Emissions US

FCC Part 15/CISPR22 Class B ANSI C63.4

UK

EN55022

ANSI C63.4

Conducted Canada

ICES-003/CISPR22 Class B

ANSI C63.4

Emissions United States

FCC Part 15/CISPR22 Class B ANSI C63.4

UK

EN 55022

ANSI C63.4
EN50082-1

Safety

Canada

CSA C22.2 No. 950-95 (CUL)

US

UL 1950 edition 3

UK

EN 60950

International

IEC 950 edition 2

This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. The limits are designed
to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.

NOTE

WARNING

Use only UL CSA/cUL approved Class 2 Wall Mount

Power Supply with a rated output of 12VAC.

Summary of Contents for Station Port Adapter DS30

Page 1: ... DS30 Station Port Adapter Installation Guide ...

Page 2: ...uipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules The limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc...

Page 3: ...6 129 mm x 1 22 36mm WEIGHT Estimated 20 ounces 567 grams includes bezel and PCB but not wall mounted power supply POWER Country Output Input Rating North America 12VAC 600mA 110VAC United Kingdom 12VAC 600mA 240VAC Australia 12VAC 600mA 240VAC RELIABILITY Mean time before failure MTBF target is greater than 20 years using Mil Std 217F method TBD reliability calculations FUNCTIONAL Multiplexes up ...

Page 4: ...nector of adapter 4 Plug power cord into AC Power Connector 5 Plug the adapter power into anAC wall outlet WARNING Use only UL CSA cUL approved Class 2 Wall Mount Power Supply with a rated output of 12VAC Figure 2 TCM Loop RJ 45 Pinout Connections Female RJ 45 JP1 TCM Loops 1 4 4 3 2 1 1 2 3 4 8 7 6 5 4 3 2 1 Loops 1 4 Pins 1 8 To Norstar KSU To Adapter RJ 45 Connector Female RJ 45 JP1 TCM Loops 5...

Page 5: ...ction TCM Loop LED port light Inactive port Invalid Check corresponding is off connection port connection TROUBLESHOOTING Table 3 Troubleshooting Guide NOTE Timing master uses highest numbered TCM Loop connected port to synchronize DS 30 link The DS30 Station Port Adapter is compatible with ACCESS 2 6 ver 6 52 and higher within application products running on the NAM II platform Systems with previ...

Page 6: ... Norstar is a trademark of Northern Telecom P0878745 Issue 01 Printed in the United States ...

Reviews: