8-4
Ordering information and system engineering rules
Optical Multiservice Edge 6130 NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Bay equipping rules
This section provides equipping rules for OME6130 installation in a bay. The
OME6130 shelf can be mounted in a variety of telecommunications equipment
bays, including 19”, 21”, and 23” standard bays.
Refer to
for OME6130 equipment rack space requirements.
Shelf equipping rules
This section lists the equipping rules for the OME6130 shelf.
For more information on the OME6130 chassis, refer to
.
Engineering rules
1
Each shelf at an OME6130 site is a stand-alone network element.
2
The node capability is provisioned to either STM-1 or STM-4 during initial
commissioning. The two SFP interfaces of the 2x155/622M aggregate
circuit pack are operating at the rate of the node capability value. The
appropriate SFPs (i.e. STM-1 or STM-4 rate) must be selected for the
2x155/622M aggregate circuit pack.
3
Each shelf requires the following components:
— two power supply units (one in slot 1 and one in slot 3)
— one OAM circuit pack in slot 2
— one 2x155/622M aggregate circuit pack in slot 6
— one filler panel in slot 7 (slot reserved for future release)
— one filler panel for each slots 4, 5, 8 and 9 (if no tributary circuit packs
are used)
— one fan module in slot 10
Note:
The SFPs interfaces must be ordered separately.
4
Each shelf is capable of supporting up to four tributary circuit packs (slots
4, 5, 8 and 9).
5
No fiber slack storage is provided for fibers terminating on the OME6130
shelf. Cable relief off the shelf can be handled using the routing brackets
provided with the OME6130 Assembly Kit.
Table 8-3
OME6130 equipment rack space requirements
Equipment
Rack units required
OME6130 shelf with dual DC power feeds (NT6Q60AA)
4U
75 ohm BNC Termination Panel (NT6Q71EA)
1U