PRI installation: RT
553-2901-200 Standard 11.00 August 1996
Installing the QPC720 PRI
This procedure describes how to install the QPC720 PRI card in an RT.
Procedure 4
Installing the QPC720 PRI in an RT
1
Determine the cabinet and shelf location of the circuit card to be
installed. The following slots can be used if they are not required for
other cards.
2
Unpack and inspect circuit cards.
3
Set option switches on the PRI circuit card. See
.
4
Install PRI QPC720 card in the assigned shelf and slot.
5
Install network QPC414 card (if no network loop connection is
available).
6
If required, install I/O adapters in I/O panel.
7
Run and connect the PRI cables.
show the RT PRI
8
If required, install connecting blocks at MDF or wall-mounted
cross-connect terminal.
9
If required, designate connecting blocks at MDF or wall-mounted
cross-connect terminal.
10
If required, install CSU or Echo Canceller.
11
Cross-connect PRI cables.
12
Add related configuration data into Meridian 1 system memory. Refer
to the work order.
13
Run PRI verification tests.
Table 8
Shelf and slot location of QPC720 in RT
Shelf
Slot
Network
5–10
DTI Expansion tier
2–9