Page 223 of 290
Line cards
Description
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on
the analog message waiting line card. When the card is used to service
off-premise telephones, primary and secondary MDF protection must be
installed. Details on installing protection devices are given in “Off-premise
line protection” on page 48. Off-premise telephones served by cable pairs
routed through the central office, or crossing a public right-of-way, can be
subject to a requirement for on-card protection, and MDF protectors may not
be acceptable. Check local regulations before providing such service.
Environmental specifications
Table 58 lists the environmental specifications for the analog message
waiting line card.
Table 58
Analog message waiting line card—environmental specifications
Parameter
Specifications
Operating temperature
0° to +60° C (+32 to +140° F), ambient
Operating humidity
5 to 95% RH (noncondensing)
Storage temperature
–40° to +70° C (–40° to +158° F)
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......