NT5D11 Line-side T1 Interface Card
Page 125 of 290
Line cards
Description
Test 2, external loopback, assumes an external loopback is applied to the T1
link. Test data is generated and received by the line-side T1 card on all
timeslots. If test 1 passes but test 2 fails, it indicates that the T1 link is
defective between the line-side T1 card and the external loopback location. If
test 1 was not run and test 2 fails, the T1 link or the line-side T1 card could
be defective. To isolate the failure to the T1 link, tests 1 and 2 must be run in
tandem. Figure 27 demonstrates how an external loopback is applied to the
T1 link.
Figure 26
MMI Local loopback test
Figure 27
MMI External loopback test
T-1 link
Line side
T-1
interface
card
Customer
premise
equipment
(CPE)
Common
Equipment
Meridian 1
External
network
T-1 link
553-7562
T-1 link
Line side
T-1
interface
card
Customer
premise
equipment
(CPE)
Common
Equipment
Meridian 1
External
network
T-1 link
553-7563
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......