![Nortel Meridian 1 Mini-Carrier Remote Description, Installation, And Maintenance Download Page 83](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402083.webp)
Installation and configuration
Page 83 of 150
Mini-Carrier Remote
Description, Installation, and Maintenance
Figure 20
DISPLAY CONFIG (D C) screen
DISPLAY CONFIG DISTANT (D C D)
This command displays the distant-end mini-carrier interface card’s
configuration settings. Its display is similar to Figure 20.
DISPLAY STATUS (D S)
This command displays the current condition of each link controlled by the
near-end mini-carrier interface card. Its display is similar to Figure 21 or
Figure 22.
Figure 21
DISPLAY STATUS (D S) (at local site) screen
MCR::>d c
MCR S/N Firmware Version V6.1C 14:56:17 03/17/98
Local Site
Alarms Enabled: YES
Link 0 Equipped
Link 1 Equipped
Alarm Level 1 Threshold Value E-5 Threshold Duration (in seconds) 10
Alarm Level 2 Threshold Value E-4 Threshold Duration (in seconds) 10
Frame Slips Alarm Level Threshold 100 Threshold Duration (in minutes) 2
Dip Switch S2 (U23) Settings (S1..S8) OFF OFF OFF OFF OFF OFF OFF OFF
Dip Switch S3 (U51) Settings (S1..S8) ON OFF OFF OFF OFF OFF OFF OFF
MCR::>
MCR::>d s
MCR S/N Firmware Version V6.1C 14:56:26 03/17/98
Local Site:
Link 0 Alarm Level 0
Link 1 Alarm Level 0
LMX 0 S/N NNTM1831R0LV F/W V6.1C Status - NORMAL
LMX 1 S/N NNTM1831TE22 F/W V6.1C Status - NORMAL
LMX 2 S/N NNTM1831TE25 F/W V6.1C Status - NORMAL
MCR::>