![Nortel Meridian 1 Mini-Carrier Remote Description, Installation, And Maintenance Download Page 60](http://html1.mh-extra.com/html/nortel/meridian-1-mini-carrier-remote/meridian-1-mini-carrier-remote_description-installation-and-maintenance_1706402060.webp)
Page 60 of 150
Installation and configuration
P0914209
Standard 3.00
April 2000
Table 9 lists the default settings for each LMI DIP switch position:
Table 10 lists all possible addresses for an LMI. The card’s address is set with
switch SW2 (@ U23), positions 1 through 6. The address is used to identify
a specific LMI in a daisy chain configuration.
Table 9
LMI standard (default) switch settings
Switch
Switch positions
1
2
3
4
5
6
7
8
SW2 @ U23 OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW3 @ U51 ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Table 10
LMI maintenance daisy chain addresses
LMI
Address
SW2 at U23 positions 1-5 (1 = ON, 0 = OFF)
1
2
3
4
5
0
0
0
0
0
0
1
1
0
0
0
0
2
0
1
0
0
0
3
1
1
0
0
0
4
0
0
1
0
0
5
1
0
1
0
0
6
0
1
1
0
0
7
1
1
1
0
0
8
0
0
0
1
0
9
1
0
0
1
0