DMS-10 H/W 400 Generic Compatibility Report for North America 3/9/98
C = Compatible
I= Incompatible
Description
Product Engineering
Code
402.5X
403.XX
404.XX
INS
B/L
Vtg.
405.XX
406.10
406.22
408.11
409.11
410.10
411.10
411.20
NT3T72AA
PCP, BUS EXTENDER, I/O
E
I
I
I
I
I
I
I
I
I
I
I
NT3T72AB
PCP, BUS EXTENDER, I/O
A
I
I
C
C
C
C
C
C
C
C
C
NT3T72AC
PCP, BUS EXTENDER, I/O
A
C
C
C
C
C
C
C
C
C
C
C
NT3T72AC
40X.XX
NOTE: MINIMUM REQUIRED FOR 400 GENERIC APPLICATIONS.
NT3T72AD
PCP, BUS EXTENDER, I/O, AD
B
C
C
C
C
C
C
C
C
C
C
C
NT3T72AD
402.5X
NOTE: NOT COMPATIBLE IF SLC-96 INTERFACE IS EQUIPPED.
NT3T72AD
403.XX
NOTE: NOT COMPATIBLE IF SLC-96 INTERFACE IS EQUIPPED.
NT3T72AE
PCP, BUS EXTENDER, I/O
04
C
C
C
C
C
C
C
C
C
C
C
NT3T73AB
IO BUS TERMINATOR
A
C
C
C
C
C
C
C
C
C
C
C
NT3T73BB
IO BUS TERMINATOR
A
C
C
C
C
C
C
C
C
C
C
C
NT3T74AA
PCP, MEMORY, 256K
C
C
C
I
I
I
I
I
I
I
I
I
NT3T75AA
PCP, CONTROLLER, MEMORY
F
C
C
I
I
I
I
I
I
I
I
I
NT3T76CA
PCP, CONTROL & TIMING, CPU
F
C
C
I
I
I
I
I
I
I
I
I
NT3T76CA
403.XX
NOTE: NOT COMPATIBLE IF SLC-96 INTERFACE IS EQUIPPED.
I
I
NT3T76CB
PCP, CONTROL & TIMING, CPU
B
C
C
I
I
I
I
I
I
I
I
I
NT3T76EA
PCP, CONTROL & TIMING, CPU
A
C
C
I
I
I
I
I
I
I
I
I
NT3T77BA
PCP, CPU FUNCTION
A
C
C
I
I
I
I
I
I
I
I
I
NT3T78AA
PCP, INTERFACE, CPU
A
I
I
I
I
I
I
I
I
I
I
I
NT3T78BA
PCP, INTERFACE, CPU
A
I
I
I
I
I
I
I
I
I
I
I
NT3T78BB
PCP, CPU INTERFACE
A
C
C
I
I
I
I
I
I
I
I
I
NT3T79BA
PCP, CPU MISCELLANEOUS
C
I
I
I
I
I
I
I
I
I
I
I
NT3T79BB
PCP, CPU MISCELLANEOUS
A
C
C
I
I
I
I
I
I
I
I
I
NT3T80AA
PCP, INTERFACE, SERIAL DATA
A
C
C
C
C
C
C
C
C
C
C
C
NT3T80BA
PCP, INTERFACE, SERIAL DATA
C
I
I
C
C
C
C
C
C
C
C
C
NT3T80BA
405.1X
NOTE: MINIMUM REQUIRED TO SUPPORT I/O PORT EXPANSION.
NT3T80BA
404.XX
NOTE: MINIMUM AT 404.30 FOR SIMPLIFIED MESSAGE DISK INTERFACE (SMDI)
NT3T80BB
PCP, DUAL SERIAL DATA INTERFACE
01
C
C
C
C
C
C
C
C
C
C
C
NT3T80BB
4XX.XX
NOTE: MINIMUM REQ. FOR GROUND ISOLATION - PAIR W/ NT3T45CC/DC
NT3T82AA
PCP, CONTROL, ESA SWITCH
A
C
C
C
C
C
C
C
C
C
C
C
NT3T83AA
PCP, ESA SWITCH
A
C
C
C
C
C
C
C
C
C
C
C
NT3T87AA
PCP, BUS TERMINATOR, I/O
A
C
C
C
C
C
C
C
C
C
C
C
NT3T87BA
PADDLEBOARD, IOI SIGNAL
A
C
C
C
C
C
C
C
C
C
C
C
NT3T87BB
PADDLEBOARD, IOI SIGNAL
01
C
C
C
C
C
C
C
C
C
C
C
NT3T88AE
PADDLEBOARD, I/O BUS B
A
C
C
C
C
C
C
C
C
C
C
C
NT3T88BE
PADDLEBOARD, I/O BUS A
A
C
C
C
C
C
C
C
C
C
C
C
NT3T88CA
PADDLEBOARD, I/O BUS B
01
C
C
C
C
C
C
C
C
C
C
C
NT3T88DA
PADDLEBOARD, I/O BUS A
01
C
C
C
C
C
C
C
C
C
C
C
NT3T89AA
PCP, CONVERTER, POWER
C
C
C
C
C
C
C
C
C
C
C
C
NT3T89AA
40X.XX
NOTE: COMPATIBLE WITH J1T69A ONLY. NOT COMPATIBLE WITH J1T91A DRIVE.
NT3T89AB
PCP, CONVERTER, POWER
B
C
C
C
C
C
C
C
C
C
C
C
Due to variable equipment/feature combinations, this report may not highlight all conditions for compatibility. Forward inquiries to NTI Customer Service.
Northern Telecom Confidential
Page 11