Page 72 of 120
Configuring ISDN BRI hardware
553-3001-218 Standard 2.00 September 2004
Procedure 20
Cross-connecting the DSLs at the cross-connect terminal
To cross-connect SILC and/or UILC ports to the building wiring:
1
Identify the card type (SILC or UILC) at the cross-connect terminal.
2
Identify the transmit and receive connections for the SILC and the TIP and
RING connections for the UILC from the label of the distribution strip.
to identify ports and their connections for a
SILC or UILC.
3
Identify building wires connected at the cross-connect terminal.
4
Cross-connect the pins from the SILC or UILC to the building wiring.
5
Repeat this procedure for each DSL.
End of Procedure
Table 16 identifies SILC and UILC port assignments connectors at the cross-
connect terminal.
Table 16
SILC and UILC port assignments connectors at cross-connect terminal
(Part 1 of 2)
SILC port
signals
UILC port
signals
Connector
pin number
and wire
color code
Wire
color
codes
Card ports
0 TX-
0 TX+
0 RX-
0 RX+
0 T
0 R
26
1
27
2
W-BL
BL-W
W-O
O-W
Port 0
1 TX-
1 TX+
1 RX-
1 RX+
1 T
1 R
28
3
29
4
W-G
G-W
W-BR
BR-W
Port 1
Summary of Contents for Communication Server 1000M
Page 2: ......
Page 4: ...Page 4 of 120 Revision history 553 3001 218 Standard 2 00 September 2004...
Page 12: ...Page 12 of 120 About this document 553 3001 218 Standard 2 00 September 2004...
Page 16: ...Page 16 of 120 Preparing for installation 553 3001 218 Standard 2 00 September 2004...
Page 52: ...Page 52 of 120 Installing ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 90: ...Page 90 of 120 Configuring ISDN BRI hardware 553 3001 218 Standard 2 00 September 2004...
Page 98: ...Page 98 of 120 Preparing the system 553 3001 218 Standard 2 00 September 2004...
Page 120: ...Page 120 of 120 Generating traffic reports 553 3001 218 Standard 2 00 September 2004...
Page 121: ......