Carrier Remote IPE cabinet installation
113
Procedure 27
Connecting the attendant to the Carrier Remote IPE cabinet
Step
Action
1
Connect the attendant console power cord to P4 connector (±15
V power pins) on the Carrier Remote IPE cabinet backplane.
2
Install and configure the attendant console.
Refer to Telephones and Consoles Fundamentals
(NN43001-567) ().
--End--
Connecting the PFTU to the Carrier Remote IPE cabinet
In the Carrier Remote IPE cabinet option, the Power Fail Transfer Unit
(PFTU) is connected as shown in
Figure 20 "Connecting the PFTU to the
Carrier Remote IPE cabinet" (page 114)
.
To make this connection, follow the steps in
PFTU to the Carrier Remote IPE cabinet” (page 113)
.
Procedure 28
Connecting the PFTU to the Carrier Remote IPE cabinet
Step
Action
1
Install the PFTU near the MDF and connect it to the MDF
according to the instructions in the PFTU user manual.
2
Install the NT7R86AA cable between the PFTU and the
NT7R60AA Carrier/Alarm Panel assembly connector DB-15
female (Alarm) connector on the Carrier Remote IPE cabinet.
For more information on how to install the PFTU, refer to
Communication Server 1000M and Meridian 1 Large System
Installation and Commissioning (NN43021-310) ().
--End--
Figure 20 "Connecting the PFTU to the Carrier Remote IPE cabinet" (page
114)
illustrates the front view of the Carrier Remote IPE cabinet. It shows
the connection of the NT7R60AA Carrier/Alarm Panel assembly DB-15
female (Alarm) connector on the Carrier Remote IPE cabinet linking the
cabinet to the PFTU and the MDF.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.