Step #3: Initiate Upgrade Process
Software Upgrade via SNMP
Use the following procedure to upgrade a CM 100 using an SNMP
manager.
1. Select cable modem device to be upgraded.
2. Select the DocsDev MIB Object ID.
3. Select the Docs_Software MIB Object ID. The SNMP manager
displays the softwareInfo Table.
4. Set the Server (docsDevSwServer) IP Address to the IP Address of the
TFTP server.
5. Set the Filename (docsDevSWFilename) to the filename of the upgrade
software that you copied into the TFTP server’s default directory. Enter
only the filename. Do not enter the full path to the TFTP server’s public
directory.
Caution: All parameters must be set exactly as stated. Verify that all
previous steps are complete and accurate, especially file names and IP
Addresses. Verify that the TFTP server is ON and the loadable files are in
the TFTP server’s public directory.
6. Initiate the upgrade process by setting the AdminStatus MIB
(docsDevSWAdminStatus) to upgradeFromMgt.
You can monitor the process if your TFTP server has a display window, or
returns status information to you. The process takes about one minute.
The modem will reset itself during this process. To verify that the software
loaded correctly, examine the SysDescr MIB object, which shows the
software revision.
Summary of Contents for CM 100
Page 1: ...305471 B Rev 02 July 1999 Version 2 1 Release Notes for the CM 100 V2 1 ...
Page 6: ...CM 100 Release Notes vi 305471 B Rev 02 ...
Page 8: ...CM 100 Release Notes viii 305471 B Rev 02 ...
Page 14: ...Release Notes for the CM 100 xiv 305471 B Rev 02 ...
Page 20: ...Release Notes for the CM 100 1 6 305471 B Rev 02 ...
Page 23: ......
Page 24: ...Printed in USA ...