Nortel BCM200 Technical Configuration Manual Download Page 2

 
 
 
BCM Technical Configuration Guide   

 

 

V1.1 

 

 

 

 

     May, 2006 

 

 

_______________________________________________________________________________________________________________________ 

NORTEL 

     External 

Distribution 

    

1

 

Copyright © 2006 Nortel Networks. All rights reserved. 
NORTEL NETWORKS CONFIDENTIAL:

 

The information contained in this document is the property of Nortel 

Networks. Except as specifically authorized in writing by Nortel Networks, the holder of this document shall not 
copy or otherwise reproduce, or modify, in whole or in part, this document or the information contained herein.  
The holder of this document shall keep the information contained herein confidential and protect same from 
disclosure and dissemination to third parties and use same solely for the training of authorized individuals. 
 
Information is subject to change without notice. 
 
Nortel, the Nortel logo, Shasta, and Passport are trademarks of Nortel Networks. 

SUN, SUNLINK, and SOLARIS are trademarks of Sun Microsystems Inc. SPARC is a trademark of SPARC 
International Inc. UNIX is a trademark licensed exclusively through X/Open Company Ltd. OPENVIEW is a 
trademark of Hewlett-Packard Company. ORACLE is a trademark of Oracle Corporation. 

 
 

Disclaimer 

This engineering document contains the best information available at the time of publication in terms of supporting 
the application and engineering of Nortel products in the customer environment. They are solely for the use by 
Nortel customers and meant as a guide for network engineers and planners from a network engineering 
perspective. All information is subject to interpretation based on internal Nortel test methodologies which were 
used to derive the various capacity and equipment performance criteria and should be reviewed with Nortel 
engineering primes prior to implementation in a live environment. 

Summary of Contents for BCM200

Page 1: ...munication Manager BCM 200 400 Technical Configuration Guide Technical Configuration Guide for BRI Based Video Conferencing on BCM Enterprise Solution Engineering Document Date May 11th 2006 Document...

Page 2: ...ject to change without notice Nortel the Nortel logo Shasta and Passport are trademarks of Nortel Networks SUN SUNLINK and SOLARIS are trademarks of Sun Microsystems Inc SPARC is a trademark of SPARC...

Page 3: ...____________________________________________________________________________________________________ NORTEL External Distribution 2 Abstract This Technical Configuration Guide TCG documents one specif...

Page 4: ...nal Distribution 3 Table of Contents 1 INTRODUCTION 5 1 1 Applicability Baseline 5 1 2 Reference Network 5 2 PROGRAMMING 6 2 1 Before You Start 6 2 1 1 Pre requisites 6 2 1 2 Additional Information 6...

Page 5: ...y Module BUS 6 8 Figure 4 BRI MBM Module 1 8 Figure 5 BRI MBM Status 9 Figure 6 ISDN DNs DN 2484 10 Figure 7 ISDN DNs Line Access OLI 10 Figure 8 ISDN DNs Line Assignment 11 Figure 9 ISDN DNs Line Poo...

Page 6: ...application This document is the result of a specific customer request for configuration information regarding point to point video conference system based upon a Polycom VideoStation connected to a B...

Page 7: ...en PRI DID connection with CbC Service to the PSTN This includes the corresponding BCM DTM MBM and all associated programming Polycom VideoStation point to point video conferencing system running soft...

Page 8: ...rget line Configure OLI Loops Configure as s interface Assign DNs Routing Verify PRI pool correctly programmed Target Line Map incoming spill Polycom Program DNs Disable H 323 SIP Configure SPIDs Figu...

Page 9: ..._______________________________________________________________________________ NORTEL External Distribution 8 Figure 3 BRI Media Bay Module BUS 6 With the BRI MBM in place continue the programming by...

Page 10: ...s status to Provisioned Figure 5 BRI MBM Status 2 4 ISDN DNs The next steps consist of ensuring that the selected ISDN DNs have the necessary features and operating parameters to originate and termina...

Page 11: ...s the OLI was set to the BCM s prime DN 34190 and was padded with zeros to fill out a full 10 digit as if it was a complete public number Thus in a non PBX implementation this field would be set to a...

Page 12: ...target line for the second B channel is not needed and should not be configured Also both DNs must be identified to the BCM as Caller ID capable sets Figure 8 ISDN DNs Line Assignment The next steps...

Page 13: ...captures to ensure that each programmable field is set correctly Figure 10 Loops Associate both DNs to the loop Figure 11 Loop Assigned DNs 2 6 Routing Video calls will be dialed directly from the vi...

Page 14: ..._________________________________________________ NORTEL External Distribution 13 Figure 12 Call Routing Destination Codes Figure 13 Call Routing Route 2 7 Target Line In this example the programming...

Page 15: ...revious examples detail the programming of two complete BRI loops a total of four B channels to the video unit It should be noted that additional loops can be utilized and the programming is an extrap...

Page 16: ...your values will be different from these Admin Network Setup Call Preferences o Select ISDN Video Calls H 320 o Ensure that LAN Internet Calls H 323 is de selected o Ensure that Display IP Dialing Ext...

Page 17: ...agnostic information may indicate that they are out of service when in fact they are operational If you observe the conditions depicted in the screen captures below it is recommended that you Complete...

Page 18: ...guration Guide V1 1 May 2006 _______________________________________________________________________________________________________________________ NORTEL External Distribution 17 Figure 17 Diagnosti...

Page 19: ..._____________________________________________________________________ NORTEL External Distribution 18 Contact Us For product support and sales information visit the Nortel Networks website at http www...

Reviews: