Using the BayStack 450 10/100/1000 Series Switch
1-42
302401-D Rev 00
To configure the VLAN port membership for VLAN 1:
1.
Select Switch Configuration from the BayStack 450-12T Main Menu (or
press w).
2.
From the Switch Configuration Menu, select VLAN Configuration (or
press v).
3.
From the VLAN Configuration Menu select VLAN Configuration (or
press v).
The default VLAN Configuration screen opens (
Figure 1-26
):
Figure 1-26.
Default VLAN Configuration Screen Example
The VLAN Configuration screen settings shown in
Figure 1-26
are default
settings with all switch ports classified as untagged members of VLAN 1.
Figure 1-27
shows the VLAN Configuration screen after it is configured to
support the VLAN 3 broadcast domain shown in
Figure 1-25
(VLAN Name is
optional).
VLAN Configuration
Create VLAN: [ 1 ]
Delete VLAN: [ ]
VLAN Name: [ VLAN #1 ]
Port Membership
1-6 7-12
------ ------
Unit #1 UUUUUU UUUUUU
KEY: T = Tagged Port Member, U = Untagged Port Member, - = Not a Member of VLAN
Use space bar to display choices, press <Return> or <Enter> to select choice.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.
kombk.book Page 42 Tuesday, June 29, 1999 3:25 PM
Summary of Contents for BayStack 450 Switch
Page 6: ...kombk book Page vi Tuesday June 29 1999 3 25 PM ...
Page 14: ...kombk book Page xiv Tuesday June 29 1999 3 25 PM ...
Page 26: ...kombk book Page xxvi Tuesday June 29 1999 3 25 PM ...
Page 132: ...kombk book Page 24 Tuesday June 29 1999 3 25 PM ...
Page 226: ...kombk book Page 94 Tuesday June 29 1999 3 25 PM ...
Page 236: ...kombk book Page 10 Tuesday June 29 1999 3 25 PM ...
Page 270: ...kombk book Page 10 Tuesday June 29 1999 3 25 PM ...
Page 276: ...kombk book Page 6 Tuesday June 29 1999 3 25 PM ...