Introduction

Nortel Ethernet Routing Switch 8300

Installation — Chassis

NN46200-309

01.01

Standard

16 June 2008

Copyright © 2008 Nortel Networks

.

Summary of Contents for 8300 Series

Page 1: ...Nortel Ethernet Routing Switch 8300 Installation Chassis Release 4 1 Document Revision 01 01 www nortel com NN46200 309 324403 A Rev 01 ...

Page 2: ...d to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks All other trademarks are the property of their respective owners ATTENTION For information about the...

Page 3: ...ssis installation fundamentals 23 Ethernet Routing Switch 8310 chassis 23 Ethernet Routing Switch 8306 chassis 25 Power supplies 26 Fan trays 27 Hardware requirements 28 Shipment contents 28 Successful installation verification 32 Ethernet Routing Switch 8310 and 8306 chassis installation 33 Chassis installation procedures 33 Chassis installation time requirements 35 Reducing the chassis weight 35...

Page 4: ...tions 55 Environmental specifications 56 International regulatory requirements 56 Ethernet Routing Switch 8306 chassis specifications 57 Physical specifications 57 Environmental specifications 58 International regulatory requirements 58 Ethernet Routing Switch 8301 AC power supply specifications 59 Ethernet Routing Switch 8302 AC power supply specifications 60 Ethernet Routing Switch 8005DC power ...

Page 5: ...ectromagnetic Compliance EMC Statements of Compliance FCC Statement USA only This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equi...

Page 6: ... 2004 108 EC Conformity is declared by the application of EN 55 022 Class A CISPR 22 CAUTION This device is a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users are required to take appropriate measures necessary to correct the interference at their own expense EN 55 024 Statement This is to certify that the Nortel 8300 Ser...

Page 7: ...VCCI Statement Japan Nippon only This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI for information technology equipment If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions BSMI Statement for 8310 and 8306 Chassis Taiwan only This is a Class A...

Page 8: ... life batteries and it is very possible that you will never need to replace them However should you need to replace them refer to the individual component manual for directions on replacement and disposal of the battery NOM Statement 8310 and 8306 Chassis Mexico only The following information is provided on the devices described in this document in compliance with the safety requirements of the No...

Page 9: ...ant supply two supplies or two supplies one redundant supply configurations 8005DC 48 to 60 VDC 42 to 34 A single supply single supply one redundant supply two supplies or two supplies one redundant supply configurations Información NOM unicamente para México La información siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento en cumplimiento con los requisit...

Page 10: ...nfiguraciones de una fuente redundante 8005DIDC 40 to 75 VDC 48 75 to 32 5 A una fuente una fuente configuraciones de una fuente redundante dos fuentes o dos configuraciones de una fuente redundante 8005DC 48 to 60 VDC 42 to 34 A una fuente una fuente configuraciones de una fuente redundante dos fuentes o dos configuraciones de una fuente redundante Denan Statement Japan Nippon only Safety Message...

Page 11: ...ir une décharge électrostatique et d éviter d endommager les produits Nortel CAUTION ACHTUNG ESD ESD Hinweise bieten Information dazu wie man die Entladung von statischer Elektrizität und Folgeschäden an Nortel Produkten verhindert CAUTION PRECAUCIÓN ESD Descarga electrostática El aviso de ESD brinda información acerca de cómo evitar una descarga de electricidad estática y el daño posterior a los ...

Page 12: ...ar posibles interrupciones del servicio o el daño a los productos Nortel CAUTION CUIDADO Os avisos de cuidado oferecem informações sobre como evitar possíveis interrupções do serviço ou danos aos produtos da Nortel CAUTION ATTENZIONE Le indicazioni di attenzione forniscono informazioni per evitare possibili interruzioni del servizio o danni ai prodotti Nortel Warning Notice WARNING Warning notices...

Page 13: ... serious personal injury or death from high voltage or electric shock DANGER La mention Danger Tension élevée fournit des informations sur les moyens de prévenir une situation ou une condition qui pourrait entraîner un risque de blessure grave ou mortelle à la suite d une tension élevée ou d un choc électrique DANGER GEFAHR Hinweise mit Vorsicht Hochspannung bieten Informationen dazu wie man Situa...

Page 14: ... moyens de prévenir une situation ou une condition qui pourrait entraîner un risque de blessure grave ou mortelle DANGER GEFAHR Gefahrenhinweise stellen Informationen darüber bereit wie man Situationen oder Umständen verhindert die zu schweren Personenschäden oder Tod führen können DANGER PELIGRO Los avisos de Peligro brindan información acerca de cómo evitar una situación o condición que pueda ca...

Page 15: ...s Nortel Networks grants you a license to use the Software only in the country where you acquired the Software You obtain no rights other than those granted to you under this License Agreement You are responsible for the selection of the Software and for the installation of use of and results obtained from the Software 1 Licensed Use of Software Nortel Networks grants Customer a nonexclusive licen...

Page 16: ...IED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON INFRINGEMENT Nortel Networks is not obligated to provide support of any kind for the Software Some jurisdictions do not allow exclusion of implied warranties and in such event the above exclusions may not apply 3 Limitation of Remedies IN NO EVENT SHALL NORTEL NET...

Page 17: ... or certify its destruction 3 Customer is responsible for payment of any taxes including personal property taxes resulting from Customer s use of the Software Customer agrees to comply with all applicable laws including all applicable export and import laws and regulations 4 Neither party may bring an action regardless of form more than two years after the cause of the action arose 5 The terms and...

Page 18: ...18 Software license Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 19: ...nformation see Ethernet Routing Switch 8005DC power supply specifications page 61 Dual input DC DC switching power supply Release 4 1 introduces a dual input DC DC switching power supply the 8005DI DC For more information see Ethernet Routing Switch 8005DI DC power supply specifications page 62 Other changes See the following sections for information about changes that are not feature related Docu...

Page 20: ...20 New in this release Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 21: ...rnet Routing Switch 8300 and includes technical specifications for the chassis and modules Prerequisites Before you install the Ethernet Routing Switch 8300 chassis ensure that you use standard cable system practices to install all network wiring on the premises Navigation Chassis installation fundamentals page 23 Ethernet Routing Switch 8310 and 8306 chassis installation page 33 Switch operations...

Page 22: ...22 Introduction Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 23: ...n about the following chassis types Ethernet Routing Switch 8310 chassis Ethernet Routing Switch 8306 chassis Navigation Ethernet Routing Switch 8310 chassis page 23 Ethernet Routing Switch 8306 chassis page 25 Power supplies page 26 Fan trays page 27 Site requirements page 27 Hardware requirements page 28 Successful installation verification page 32 Ethernet Routing Switch 8310 chassis The Ethern...

Page 24: ...lane that supports 802 3af PoE The PoE feature requires the following components Ethernet Routing Switch 8306 or 8310 chassis with PoE backplane Ethernet Routing Switch 8301AC or 8302AC power supply Ethernet Routing Switch 8393SF CPU or 8394SF CPU module and a choice of either of the following Ethernet Routing Switch 8348TX PWR module Ethernet Routing Switch 8348GTX PWR module CAUTION Risk of equi...

Page 25: ...rnet Routing Switch 8306 chassis has three bays for either AC or DC power supplies and a single fan tray for cooling Figure 2 8306 chassis and components page 26 also shows the location of customer replaceable components in the 8306 chassis The Ethernet Routing Switch 8306 chassis includes a PoE backplane that supports 802 3af PoE The PoE feature requires the following components Ethernet Routing ...

Page 26: ...rations A mixed configuration can damage the modules and void your warranty Figure 2 8306 chassis and components Power supplies The Ethernet Routing Switch 8306 and 8310 chassis each provide three bays for either AC or DC power supplies The Ethernet Routing Switch 8306 and 8310 chassis supports the following AC power supplies 8301AC 8302AC The Ethernet Routing Switch 8306 and 8310 chassis supports...

Page 27: ...high capacity fans 8306 One fan tray containing six high capacity fans A control monitor circuit board in the fan tray reports temperature and fan operating status to the network management software A green light emitting diode LED indicates that the fan tray is operating correctly For information about installing the fan see Nortel Ethernet Routing Switch 8300 Installation Fan Tray NN46200 302 Si...

Page 28: ...00 chassis operation For more information see the following table Table 2 Environmental requirements Altitude Humidity Temperature 0 10 000 feet ft 0 3 048 meters m 5 85 noncondensing 32 F 104 F 0 C 40 C stable Hardware requirements This section includes information about the hardware shipped with the 8306 and 8310 chassis Shipment contents In addition to the Ethernet Routing Switch 8310 or 8306 c...

Page 29: ...ontaining wafer head screws each being 0 190 inches wide 32 threads to the inch and 0 75 inches long with flat nylon washers The 8310 chassis ships with 14 of each The 8306 chassis ships with 10 of each Mount the chassis in an equipment rack 2 side cable management brackets Manage network interface cables Rubber footpads Keep the chassis from slipping when mounting it on a flat surface Console cab...

Page 30: ...ion fundamentals Figure 3 Items in the Ethernet Routing Switch 8310 chassis shipping container Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 31: ...ables tools and other equipment that you need The following sections describe the equipment you must supply Management console page 31 Cables page 32 Mounting hardware for the 8310 8306 chassis page 32 Management console To configure startup options and to monitor the results of startup diagnostics you can attach an optional PC or laptop VT 100 console or an equivalent such as a PC terminal emulat...

Page 32: ...verification In a normal power up sequence the LEDs light as follows 1 When power is applied to the Ethernet Routing Switch 8300 Series the green LED on each power supply and fan tray turns on and the Online LED for each module lights amber 2 Each module initiates a self test during which the port and module LEDs display various patterns to indicate the progress of the self test 3 On successful co...

Page 33: ... that the items in the shipping container match those on the shipment packing list Use Table 3 Chassis shipping accessories Ethernet Routing Switch 8310 and 8306 chassis page 29 as a checklist when verifying the contents of the shipping container Verify that you have supplied all the other required hardware Ensure that your installation site meets the physical electrical and environmental requirem...

Page 34: ...igation Chassis installation time requirements page 35 Reducing the chassis weight page 35 Installing the chassis on a flat surface page 35 Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 35: ...educe the risk of personal injury or equipment damage This procedure requires approximately 5 minutes to complete Procedure steps Step Action 1 Remove the power supply filler panels For more information see Nortel Ethernet Routing Switch 8300 Installation AC Power Supply NN46200 301 2 Remove the module filler panels For more information see Nortel Ethernet Routing Switch 8300 Installation Modules ...

Page 36: ...commended to keep the unit from slipping 3 Attach all devices to the ports End Procedure job aid Chassis weight including components The following table shows the weight of each chassis including the components Chassis Maximum weight chassis and components 8310 225 pounds lb 102 kilograms kg 8306 140 lb 63 kg Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack Install t...

Page 37: ...river CAUTION See Procedure job aid Maximum number of chassis installed in 7 foot rack page 40 for the maximum number of chassis that you can install in a 7 foot rack Procedure steps Step Action 1 Hold each rack mounting bracket against one side of the chassis Make sure that the attachment holes in the bracket match the holes in the chassis Each bracket fits only one side of the chassis The bracke...

Page 38: ...et to the chassis 3 Measure the appropriate number of rack units of free vertical space inside the rack and mark the spot The following table shows the number of rack units you can allocate for each chassis Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 39: ...les on each side of the vertical rack support It is easier to complete this step with two people Make sure that the hole pairs on either side of the vertical support match horizontally 5 Insert and tighten the rack mounting screws with a Phillips screwdriver Do not overtighten the rack mounting screws Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 ...

Page 40: ...hassis that you can install in a 7 foot rack Chassis Maximum number of chassis installed in 7 foot rack 8310 3 8306 4 Installing the cable guides Install the cable guides to keep cable clusters fastened and out of the way but still accessible for maintenance Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 41: ... the rack mounting screws needed to install one cable guide 2 Slide the guide onto the loosened screws 3 Tighten the screws to secure the guide to the chassis Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 42: ...42 Ethernet Routing Switch 8310 and 8306 chassis installation End Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 43: ... removable flash memory cards page 46 Removing removable flash memory cards page 47 Protecting memory card files page 48 Powering on DC power supplies Power on the DC power supplies to provide power to the switch Prerequisites Ensure that the power supply is seated properly Procedure steps Step Action 1 On each DC power supply turn the power switch to the On position Nortel Ethernet Routing Switch...

Page 44: ...ly status LEDs and the fan LED on the 8393SF CPU or 8394SF CPU module light green After you turn on the switch each module automatically initiates a diagnostic test to verify proper module function See Successful installation verification page 32 4 Verify that air is flowing from the cooling fans out through the vents of the chassis 5 If the power supply LED remains off or if you cannot feel air f...

Page 45: ...n To correct this condition turn off both power supplies wait at least 30 seconds and then turn on both power supplies again simultaneously 2 Verify that the power LED on each power supply lights green 3 Verify that the power supply status LEDs and the fan LED on the 8393SF CPU or 8394SF CPU module light green After you turn on the switch each module automatically initiates a diagnostic test to ve...

Page 46: ...et button on the 8393SF CPU module The following figure shows the location of the Reset button on the Ethernet Routing Switch 8394SF CPU module Figure 6 Reset button on the 8394SF CPU module Installing removable flash memory cards Install a removable flash memory card in an Ethernet Routing Switch 8393SF CPU module to provide alternative storage media Procedure steps Step Action 1 Position the car...

Page 47: ...witch 8393SF CPU or 8394SF CPU module to stop using it as a storage medium Procedure steps Step Action 1 Press the eject button to the side of the memory card receptacle on the Ethernet Routing Switch 8393SF CPU or 8394SF CPU module The card pops out slightly 2 Pull the flash memory card out of the card receptacle End Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Stand...

Page 48: ...rotocol FTP or Trivial FTP TFTP server Prerequisites Remove the card from the Ethernet Routing Switch 8393SF CPU or 8394SF CPU module before changing the read write protection ATTENTION You must remove the card from the Ethernet Routing Switch 8393SF CPU or 8394SF CPU module before changing the read write protection Failure to remove the card can result in improper write protection Procedure steps...

Page 49: ...ing memory card files 49 4 Reinsert the memory card into the card receptacle End Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 50: ...50 Switch operations Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 51: ... supply and up to three power supplies are supported DS1402008 E5 8306 6 slot PoE chassis Includes chassis dual backplane two fan trays RS232 cable the for the management console rack mount kit and cable guide kit Requires at least one 83XX power supply and up to three power supplies are supported DS1404076 E5 Ethernet Routing Switch 8393SF CPU Switch Fabric module with 8 Gigabit Ethernet SFP slot...

Page 52: ...ort autonegotiating 10BASE T 100BASE TX or 1000BASE T Ethernet interface module DS1404098 E5 Ethernet Routing Switch 8324FX 24 Port 100Base FX Ethernet interface module DS1404093 E5 Ethernet Routing Switch 8348GTX module 48 port Autosensing 10Base T 100Base TX 1000Base T Ethernet interface module DS1404094 E5 Ethernet Routing Switch 8348GTX PWR module 48 port Autonegotiating 10BASE T 100BASE TX 10...

Page 53: ...d DS1405x16 E5 8302AC 100 240 V AC Power Supply At least one power supply is required for each 83xx chassis Provides up to 400W of PoE Does not include a power cord DS1405011 E5 8005DC 48 60 V DC Power Supply At least one power supply is required for each 83xx chassis DS1405017 E6 8005DI DC 40 70 V DC Power Supply At least one power supply is required for each 83xx chassis Nortel Ethernet Routing ...

Page 54: ...54 Part Numbers Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 55: ...g Switch 8005DC power supply specifications page 61 Ethernet Routing Switch 8005DI DC power supply specifications page 62 Ethernet Routing Switch 8310 chassis specifications The following sections describe the specifications of the Ethernet Routing Switch 8310 chassis Physical specifications The following table lists the physical specifications of the Ethernet Routing Switch 8310 chassis Table 5 E...

Page 56: ...ge temperature 25 C to 70 C 13 F to 158 F Operating humidity 85 maximum relative humidity noncondensing Storage humidity 95 maximum relative humidity noncondensing Operating altitude 3 048 meters m 10 000feet ft maximum Storage altitude 3 048 m 10 000 ft maximum Free fall drop ISO 4180 s NSTA 1A Vibration IEC 68 2 6 34 Shock bump IEC 68 2 27 29 International regulatory requirements The following t...

Page 57: ...sis for certification IEC 60950 current edition with all CB member deviations U S UL60950 Canada CSA 22 2 No 60950 Europe EN60950 CE Marking Australia New Zealand AS NZS 3260 Mexico NOM 019 SCFI 1998 Ethernet Routing Switch 8306 chassis specifications The following sections describe the specifications of the Ethernet Routing Switch 8306 chassis Physical specifications The following table lists the...

Page 58: ...y noncondensing Storage humidity 95 maximum relative humidity noncondensing Operating altitude 3048 m 10 000 ft maximum Storage altitude 3048 m 10 000 ft maximum Free fall drop ISO 4180 s NSTA 1A Vibration IEC 68 2 6 34 Shock bump IEC 68 2 27 29 International regulatory requirements The following table lists the international regulatory requirements of the Ethernet Routing Switch 8306 chassis Tabl...

Page 59: ...nada CSA 22 2 No 60950 Europe EN60950 CE Marking Australia New Zealand AS NZS 3260 Mexico NOM 019 SCFI 1998 Ethernet Routing Switch 8301 AC power supply specifications The following table lists the power specifications for the 8301 AC power supply Table 11 Ethernet Routing Switch 8301 AC power specifications AC Input Power Ratings Input voltage range nominal 100 120 VAC 200 240 VAC Input current n...

Page 60: ...s input voltage condition The maximum steady state output power is limited to a total of 870 W for any combination of output voltages currents excluding the 50 VDC source at high line 200 240 VAC nominal input voltage conditions This limitation is required to ensure maximum PoE power or 900 W total for the 50 VDC source at this input voltage condition To obtain the full output power rating of 1770...

Page 61: ... required to ensure that there is sufficient PoE power or 225 W total at this input voltage condition The maximum steady state output power is limited to a total of 950 W for any combination of output voltages currents excluding the 50 VDC source at high line 200 240VAC nominal input voltage conditions This limitation is required to ensure maximum PoE power or 450 W total for the 50 VDC source at ...

Page 62: ... lists the DC input power specifications Parameter Specifications Input voltage 40Vdc 75Vdc Input current 48 75A 32 5A Input VA maximum 1 95 kVA Input power consumption 1950 W Heat dissipation thermal output 1666 Btu hr The following table lists the DC output power specifications Parameter Specifications Output power maximum 1462 W continuous 1660 W peak with forced air cooling Modules 3 3 V 150 A...

Page 63: ...Störungen des Radio und Fernsehempfangs verursachen In diesem Fall muss der Benutzer alle notwendigen Maßnahmen ergreifen die möglicherweise nötig sind um die Störungen auf eigene Rechnung zu beheben CAUTION PRECAUCIÓN Este es un producto clase A El uso de este equipo en áreas residenciales puede causar interferencias nocivas en cuyo caso se requerirá que los usuarios tomen cualquier medida necesa...

Page 64: ... ce produit Assurez vous que le bracelet antistatique est en contact avec votre peau CAUTION ACHTUNG ESD Um Schäden durch elektrostatische Entladung zu verhindern tragen Sie bei der Instandhaltung dieses Produkts immer ein antistatisches Band am Handgelenk das mit einer ESD Buchse verbunden ist Stellen Sie sicher dass das Band am Handgelenk Kontakt zur Haut hat CAUTION PRECAUCIÓN ESD Descarga elec...

Page 65: ...tatiche indossare sempre un polsino antistatico collegato a una presa di scarico elettrostatico ESD durante la manutenzione del prodotto Accertarsi che il polsino sia a contatto con la pelle Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 66: ...66 Translations of safety messages Nortel Ethernet Routing Switch 8300 Installation Chassis NN46200 309 01 01 Standard 16 June 2008 Copyright 2008 Nortel Networks ...

Page 67: ......

Page 68: ...ent is believed to be accurate and reliable except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks All other trademarks ...