Nortek Scour Monitor Quick Manual Download Page 2

 

Please check that all  
expected items are  
included in the shipment: 

 

 The instrument  

 External power/signal cable 

 NORTEK equipment storage 

    box/toolkit 

 USB to serial converter 

 AC/DC voltage transformer  

 Power cable  

    (European or American)  

 Software on USB memory stick 

 Final test check list 

 Packing list 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the Nortek software  

The instrument’s software is 
located on the attached 
memory stick.  
 
Please check the web 
regularly for updates on both 
software and firmware. 

 

 

This Quick Guide provides you with the basic information you need to get the 
Scour Monitor up and running as quickly as possible. If you are familiar with the 
Nortek instruments, this guide may be all you need. If you are new to our 
instruments and software we recommend that you check the web, were you will 
find some useful information: 

www.nortekgroup.com

 

Preparation 

1.

  Make a Reception Control. The items included are listed in the column to the 

left and in the packing list. 

2.

  Connect the battery. 

3.

  Install the software located on the USB Memory stick. Once the installation is 

complete you can launch the 

AquaPro Scour

 application.  

4.

  Run a Functional Test: 

a)

  Set the

 

Measurement Interval to 1 second in the Deployment Planning 

menu (see the next section). This allows you to retrieve data every 
second. 

b)

  Start the instrument and check that all the beams produce signals. When 

the instrument pings in air, the signals will be nothing but noise. 

c)

  Submerge the instrument in either a test tank or a bucket of water. Verify 

the following readings:

 

  The signal strength observable in b) should rise noticeably 

  Battery voltage (New battery: > 13V DC) 

 

The temperature   

 

Tilt the instrument to verify the pitch and roll readings.

 

 

Configuration  

  Select 

Deployment Planning

  The activated dialog contains all parameters required to specify the operation 

of the instrument. Note that a description of each parameter can be found in 
the application help, accessible from the dialog box. The Deployment Planning 
frame on the right hand of the dialog displays performance parameters that are 
automatically updated as you change the settings

. Please pay special 

attention to the battery utilization and the memory requirements.

 

  When finished, press 

OK

 to accept the changes. By using the Open/Save 

commands in the File menu (or the corresponding toolbar buttons) the 
deployment parameters can be saved to file at any given time and re-loaded 
when it is time to actually deploy the instrument. 
 

Getting Started 

  Establish communication with the instrument. 

  Select Start Recorder Deployment. 

  Specify the date and time to start data recording. 

  In the Name field enter up to 6 characters of text to identify the data file stored 

in the reorder. 

  In the File Comment box enter up to 180 characters of text which will be 

included in the data file for the purpose of documenting the data set. 

  After pressing 

OK

 the Set Clock dialog box is displayed. We recommend 

setting the clock to PC time. The time reference is especially important in order 
to ensure proper synchronization between the instrument and other data sets 
collected independently.  

  Press 

Yes

 to continue. A confirmation dialog will display the deployment 

parameters and allow you to verify that the set-up is what you intended. 

  Press 

Confirm 

to send the configuration to the instrument. The configuration 

information from the deployment sequence is saved in a log file that has the 
same name as the deployment.  

   