1. Features and Product
Description

1.1 Features

Flush Mount

Indoor and Outdoor Use

Keypad Programmable

Self-Contained Single Door Access Control Functionality

Illuminated Backlit Keys

Keypress Feedback via Built-In Sounder

Bi-Color Red/Green LED Indicates Relay Status

Yellow LED Indicates Program Mode

120 Users

10 to 30 Volt DC Operation

12 to 24 Volt AC Operation

2 Amp Main Relay

Lock Release Output With Timer

Alarm Zone Shunt Relay

Propped Door Alarm Relay

Forced Door Alarm Relay

Remote Trigger Input (REX)

5-Year Warranty

1.2 Product Description

The model 232e Keypad is designed for security and is perfect for
self-contained access control applications. It features output relays
to release the door lock, to shunt an alarm zone, and to trigger both
a propped or forced door alert. Also, the 232e Keypad contains in-
puts for door monitor and REX. It allows up to 120 users.
All e style keypads are designed for both indoor and outdoor flush
mount applications. The electronics for each e keypad are conformal
coated in the manufacturing process in order to provide this level of
application flexibility. In addition, each e style keypad uses hard-
ened keys to assure long-term, high-quality performance. Each e
style keypad contains illuminated clear keys that make operation in
low-light situations easy and accurate. Installation is easy. All e style
keypads mount to any standard single-gang electrical box or directly
to any wall.

IEI 232e Standalone Installation/Programming Manual

2

Document # 6054004, Rev. 2.1

Summary of Contents for IEI 232e Standalone

Page 1: ...e Keypad to an Electric Strike Fail Secure 5 4 Shunting a Normally Closed Zone 5 5 Wiring Remote Trigger as Request to Exit REX Button and Door Contacts 5 6 Installing the Plug On Relay Board 5 7 Wiri...

Page 2: ...cations It features output relays to release the door lock to shunt an alarm zone and to trigger both a propped or forced door alert Also the 232e Keypad contains in puts for door monitor and REX It a...

Page 3: ...A for each alarm relay Environment Indoor and Outdoor Temperature Tolerance 20 F to 130 F Dimensions 4 5 H x 2 75 W x 0 60 D Main Relay Form C Contact Rating 2A 30VAC DC Alarm Relays Alarm Shunt Propp...

Page 4: ...pad A minimum of three user codes must be programmed into the key pad for controlling access 3 1 Tamper Requirements To meet U L requirements a U L Listed tamper switch must be in stalled in the singl...

Page 5: ...Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch IEI 232e Standalone Installation Programming Manual Document 6054004 Rev 2 1 5...

Page 6: ...of this manual and on the unit s container Mounting height can vary depending on requirements An appropri ate range is typically between 48 and 52 inches on center off the floor For outdoor installati...

Page 7: ...r REX 6 White Orange Loop Common 7 White Door Loop Monitor 8 Green Main Relay Normally Open 9 Blue Main Relay Common 10 Gray Main Relay Normally Closed Figure 4 232e Connector and Wire Harness NOTE Fo...

Page 8: ...ower supply 4 3 Wiring the 232e Keypad to an Electric Strike Fail Secure Use the following steps to connect the 232e keypad to an electric strike fail secure see Figure 6 for reference 1 Connect the r...

Page 9: ...ue wire common to the common connection on the door position switch 2 Connect the green wire normally open to the normally closed connection on the door position switch Figure 6 Wiring 232e Keypad to...

Page 10: ...hite wire door loop to the normally closed connection on the door switch NOTE By default the REX function operates the virtual lock out put only but this can be changed using command 49 In addition th...

Page 11: ...1 Propped Door K3 P2 Forced Door K4 P3 Use the wire harnesses supplied with the relay board to connect to the relays The wire colors are shown in the table below Wire Color Relay Connection Green Norm...

Page 12: ...y Board To install the relay board plug the connector onto P3 on the key pad The relay must face up towards the keypad wire harness con nector P2 IEI 232e Standalone Installation Programming Manual 12...

Page 13: ...witch 2 Wiring the propped door alarm Using P2 K3 connect the green wire normally open to the positive on the alarm device Connect the blue wire common to the positive on the power supply Connect the...

Page 14: ...keypad 7890 123456 If all 12 keypresses are accepted the keypad enters self test mode The LEDs alternate green yellow and red followed by the sounder beeping three times 2 Verify that the master code...

Page 15: ...ons time Propped Door Time rounded down to nearest 10 s of seconds entered as 00 10 through 990 defaults to 30 seconds entering a time of zero disables the function Command 45 Set Forced Door Time Opt...

Page 16: ...elete or disable the master code or supervisor code itself Add User user location code code Add User with Specific Unlock Time unlock time user location code code This command is used to program a use...

Page 17: ...uto Entry Suspend Just enter the key prior to your code followed by the key Example 23456 if the master code is four digits Error Lockout When enabled the keypad keeps track of the number of consecuti...

Page 18: ...reshold 1 through 50 defaults to 3 3 error lockout duration 1 through 255 defaults to 10 Command 40 Reset defaults only 40 00000 00000 master code all keypad options and parameters Command 46 Erase Us...

Page 19: ...he voltage to between 12 24V The master code does not work Perform the programming mode loopback and reset the master code using the programming command No LEDs are lit on the keypad Power is not reac...

Page 20: ...ter code and power down the system and restore the wire har ness to its original configuration and power the system back up First disconnect power from the system Next connect the White Yellow wire to...

Page 21: ...after obtaining IEI s Return Material Authorization IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in or malfunction of its pro...

Page 22: ......

Page 23: ......

Page 24: ......