Nortek AB 175 Installation, Operation & Parts Download Page 22

Form

 

I-A C (2-17),

 

Page

 

22

A

Adjusting of Air Outlet Louvers  7
Air Curtain Location  4
Amber Neon  19

B

Burner  19
Burner Controls  14

C

California Warning Label  3
Clearances  5

Clearances to Horizontal Vent  11

Combustible Clearances  5
Compressor Mounting Kit  19
Condensation  12
Contact  23

D

Dimensions  4
Distribution Fan  19

E

Electrical and Wiring  13

F

Fan (Venter)  19
Features  5
Flame Probe  19

G

Gas Connection Check  14
Gas Piping and Pressures  8
Gas Piping Check  14
Gas Piping Requirements and Connection  9
Gas Pressure Adjustment Procedure  15
Gas Valve  19
General Information  3

H

Hazard Intensity Levels used in this Manual  2

I

Ignition Controller  19
Ignition Electrode with HT lead  19
Installation Codes  23
INSTALLATION RECORD  23

J

Joints and Sealing  12

L

Lighting Sequence  16

M

Manifold  19
Massachusetts Requirements  3
Multiple Air Curtains  6

N

Net Weight  4

O

Orifice  19

P

Pipe Diameter  12
Position and Mounting  6
Pressure Settings  9
Pressure Switch  19
Pre Startup Check  14
Propane Conversion Kits  19

R

Receiving, Uncrating  3
Red Neon  19
Reset Limit Control with Capillary  19

S

Service  20
Shutdown  16
Single Air Curtain  6

Sizing a Gas Supply Line  8

Spare Parts  19
Startup  16

T

Technical Specifications  8

Thermister  19
Transformer  19
Trouble Shooting  17

U

Unit Wiring Diagram  13

V

Vacuum Setting Check  16
Vacuum Setting Range  16
Venting  10
Vent Pipe  10

W

Warranty  3
Wire Harness with 5 pin Terminal  19
Wire Harness with 9 pin Terminal  19
Wiring  13

INDEX

Summary of Contents for AB 175

Page 1: ...DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a...

Page 2: ...l result in severe personal injury or death and or property damage 2 WARNING Failure to comply could result in severe personal injury or death and or property damage 3 CAUTION Failure to comply could...

Page 3: ...ion to the warnings If you do not have knowledge of local requirements check with the local agencies who might have requirements concerning the installation Become familiar with the requirements of yo...

Page 4: ...on 4 0 Dimensions Clearances Features Check the supporting structure to be used to verify that it has sufficient load carrying capacity to support the weight of the air curtain assembly The air curtai...

Page 5: ...a surface or object that is necessary to ensure that a surface temperature of 90 F above the surrounding ambient temperature is not exceeded Minimum clearances are also listed on the heater rating pl...

Page 6: ...be extend slightly past the ends of the air curtains units to aid in fastening WARNING Mounting of Multiple Air Curtains may require larger support channels to insure proper support of heavier loads 5...

Page 7: ...lts at each end of the unit total of four as shown below Hex Head Bolts Button Head Socket Cap Screws Loosen the two button head socket cap screws that lock the louvers in position Note two pair on Mo...

Page 8: ...e regulator external to the unit Capacity of Piping Cubic Feet per Hour based on 0 3 i w c Pressure Drop Specific Gravity for Natural Gas 0 6 Natural Gas 1000 BTU Cubic Ft Specific Gravity for Propane...

Page 9: ...s in operation For Natural Gas The unit is set at the factory to a inlet supply pressure of 7 0 inches water column Inlet supply pressure to the valve for natural gas must be a minimum of 5 inches wat...

Page 10: ...e OR single wall 26 gauge or heavier galvanized or material of equivalent durability and corrosion resistance vent pipe is required between the air curtain combustion exhaust and the vent terminal sec...

Page 11: ...ced air inlet within 10 ft 3 1M 3 ft 0 9M above Combustion air inlet of another appliance 6 ft 1 8M Door window or gravity air inlet any building opening 4 ft 1 2M horizontally 4 ft 1 2M below 1 ft 30...

Page 12: ...for __ Vent Pipe 90 Elbow 45 Elbow inch mm feet M feet M feet M AB 175 6 152 4 30 9 1 8 2 4 4 1 2 AB 225 6 152 4 30 9 1 8 2 4 4 1 2 Any length of single wall pipe exposed to cold air or run through a...

Page 13: ...TERMINAL BLOCK CONTROL BOX L1 L2 N 1 2 3 4 5 TERMINAL BLOCK UNIT 1 2 3 4 5 HI MED L2 E OPTIONAL FACTORY WIRING FACTORY WIRING FIELD WIRING A TEMPERATURE RATING OF AT LEAST 105 DEGREES C MUST BE REPLAC...

Page 14: ...nit is positioned away from exposure to water spray rain and dripping water Check venting supports and clearances per Section 6 2 Check piping for leaks and proper gas line pressure Bleed gas lines of...

Page 15: ...e control panel cool heat selector switch to the heat position and wait for the burner to light 5 Observe the manometer reading located at the burner pressure test point 6 If an adjustment is necessar...

Page 16: ...re resetting This occurs when ever the unit has been on a prolonged stand by period This unit is fitted with an automatic spark ignition When proper airflow for combustion is proven by the air proving...

Page 17: ...2 Operation of vacuum switch 3 Replace fan Does the fan run NO Check 1 Vacuum switch tube 2 Air inlet vent for obstructions 3 Operation of vacuum switch 4 Replace fan Does the vacuum switch pull in C...

Page 18: ...ntrol panel manual on off switch position 2 Fan circuit breaker s 3 Fan contactor and associated wiring YES NO Single fan unit off Check 1 Motor thermal trip may run when cool test motor 2 Motor wirin...

Page 19: ...ch AB175 P N 205442 AB225 P N 204328 Gas Valve Natural Gas P N 270378 Manifold P N 1001152 Burner P N 1001153 Orifice Natural Gas AB175 P N 1001156 AB225 P N 1001155 Propane Conversion Kits Conversion...

Page 20: ...urtain should only be serviced by a qualified technician It is recommended that this unit be inspected serviced once a year If this unit is located in a exceptionally dusty area service should be perf...

Page 21: ...Form I A C 2 17 Page 21 NOTES...

Page 22: ...nition Controller 19 Ignition Electrode with HT lead 19 Installation Codes 23 INSTALLATION RECORD 23 J Joints and Sealing 12 L Lighting Sequence 16 M Manifold 19 Massachusetts Requirements 3 Multiple...

Page 23: ..._ ________________________________________________________ ________________________________________________________ Phone _________________________________ Model ________________ Serial No ___________...

Page 24: ...rations subject to change without notice or without incurring obligations Nortek Global HVAC LLC 2017 All rights reserved All marks are property of their respective organizations O Fallon MO I Printed...

Reviews: