The bell output can be programmed for
supervision to detect if the wire to the bell is cut.
For low current sounders,
install an 820 Resistor in
parallel with the sounder.
14DC INPUT (+)
14DC INPUT (-)
COMMON
BELL (+)
BELL (-)
Supervised bell output:
6-12VDC @ 120mA
HARDWIRED ZONE
Use Solid State Sounders ONLY
DO NOT CONNECT to an electromechanical
bell
Piezo/Siren
GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved.
14
2GIG is a registered trademark of Nortek Security & Control LLC.
WARNING:
To avoid damage to the output, do NOT connect an
electromechanical bell to these terminals .
Installation
Wiring
Hardwired loops need to be programmed for contact type .
Figure 6
Hardwired Loop Wiring
Remote Alarm Sounder
The Control Panel provides two (2) terminals for an optional
connection to a remote electronic alarm sounder.
Figure 7
Remote Alarm Sounder
WARNING:
Stranded conductors clamped under wire-
binding screws or similar parts shall have the individual
strands soldered together or arranged in a construction that
has been determined to be the equivalent.
The bell terminals can be supervised . If Q21: Siren Supervision
Time is set to (1) Enabled, and the wire between the Control
Panel and sounder is cut, the Control Panel displays a trouble
alert message for siren supervision and sends a bell trouble
report to the Central Station.
1.
Install the remote sounder in a secure location where it will
be easily heard by occupants .
2.
Route wiring from the remote sounder location to the
Control Panel’s wall cutout .
NOTE:
If the Piezo alarm siren for the remote sounder has an
extremely low current draw or the sounder produces hum or
noise, install an 820Ω resistor in parallel with the sounder.
Wireless Sensors
Install wireless sensors in the appropriate location using the Installation Instructions included with each wireless sensor as a guide .
Hardwired Loop
Hardwired loops can be programmed either Normally Open (N/O) or Normally Closed (N/C). End-of-Line Resistors (EOLR) can also
be used to supervise the loops . Only contacts should be used with the hardwired loops .
NOTE:
The Control Panel does not support powering external devices (PIR’s, etc .) .
NOTE:
Hardwired loops cannot be used for a CO or Fire sensor loop .
1.
If either of the two (2) hardwired loops are going to be used, install the contacts and then route the loop wire to the Control
Panel’s wall cutout .
2.
If end-of-line supervision is required for the loop, install a 2.2kΩ resistor (not supplied) as shown in Figure 6 Hardwired Loop