BluePass 2‐N‐1 Multi‐Tech Reader – Installation Guide 
820‐00001

 

 

Copyright © 2018 Nortek Security and Control LLC 

10020730 X5

 

 

 

This page is intended for installer use in the installation of the BluePass 2‐N‐1 Multi‐Tech Reader. 
 

Introduction 

This guide will walk a professional installer through the 
steps needed to attach a 2‐N‐1 BluePass Multi‐Tech 
Reader to an access control panel. The 2‐N‐1 supports 
125 KHz proximity fobs and cards as well as Linear 
BluePass mobile credentials. Please review the 
information below to ensure the reader is installed 
quickly and properly. 

WARNING:

  

DO NOT

 connect the reader up with 

energized wires until instructed to do so. 

Grounding 

 

The shield must run continuously from the reader to 
the panel. At the panel, the reader ground, shield 
line, and earth ground must be connected together 
at a single point.  

o

 

Do not ground the shield line at the 
reader end, as this will create a 
potential ground loop. 

Power 

 

A non‐switching power supply at the panel is 
recommended to power the reader for the highest 
noise immunity and best performance. 

 

For UL 294 Compliance, the readers shall be 
connected to a class two power limited power 
supply or control panel output. 

 

The recommended wire gauge is 24 AWG. 

Voltage 

 

The minimum reader voltage required is +6 VDC to a 
maximum of +16.0 VDC, and 12.0 VDC is 
recommended. 

 

The reader will require 100 mA (typical @ 12 VDC) in 
standard mode, 220 mA (typical @ 12 VDC) in 
advanced mode.  

 

The reader is in “standard” mode by default. 
“Advanced” mode can be configured via in‐app 
settings using the BluePass app. 

Connection 

 

Connections must be in accordance with NFPA 70. 
DO NOT connect to a receptacle controlled by a 
switch.  

Mounting the Reader 

 

If the unit is used to control a door or pedestrian 
gate, locate the unit as near as practical to the entry 
point. If the unit is mounted on or in a wall adjacent 
to the entry point, be sure the wall is sturdy. The 
repeated shock and vibration from a slamming 
access door or spring‐loaded pedestrian gate must 
be isolated from the unit.  

 

Never mount the reader directly on a moving door 
or gate. 

 

Choose a well‐lit location near the controlled 
opening. Wiring access for power, network, and 
earth ground must be available to the mounting 
location. 

Mounting 

 

Both the Mullion and Single‐gang readers can be 
mounted on a wall or any suitable flat surface. 

Mobile Device and Software 

 

The 2‐N‐1 Multi‐Tech Reader utilizes BLE version 4.0. 

 

The reader is to be used in conjunction with the 
BluePass Mobile App (Version 1.0 or higher).  

 

In order for the reader to function properly, the 
mobile device’s software must be up to date. 

 

iOS Devices: iOS 10.0 or higher 

 

Android Devices: v5.0 (Lollipop) or higher and 
peripheral mode supported. 

 

Refer to 

http://bluepass.io

 or use the QR code 

for obtaining full versions of the User and 
Installation manuals. 
 

 

 

 