302UM0017 Rev 01
PD230 Enhanced Detector User Manual
Page 40 of 37
__________________________________________________________________________
_______
POWER SUPPLY DETAILS:
Nominal Voltage: _______ V Minimum Voltage: _______ V Maximum Voltage: ________ V
AC or DC ? ______________ If AC then the Frequency _______ Hz
LOOP DETAILS
Channel 1
Channel 2
Size of loop: ____ m by ____ m
Size of loop: ____ m by ____ m
Shape of loop: _____________________
Shape of loop: _____________________
Number of Turns: _____
Number of Turns: _____
Size of wire used (mm
2
or AWG) _____________
Size of wire used (mm
2
or AWG) _____________
Type of wire insulation _____________________
Type of wire insulation _____________________
Thickness of insulation:_____________ mm
Thickness of insulation:____________ mm
How far below the surface is the loop: ________ mm
How far below the surface is the loop: _______ mm
Are there any metal objects below the loops such as concrete reinforcing, water pipes etc if yes please give
details:
_____________________________________________________________________________
____________________________________________________________________________
_____________________________________________________________________________
Are there any power cables below these loops
(Yes/No)
____ If yes please give details:
_____________________________________________________________________________
_____________________________________________________________________________
_____________________________________________________________________________
Are there any other loops in the area
(Yes/No)
____ If so how many? ________ and
how close to these loops are they? ________ m
FEEDER CABLE DETAILS
Channel 1
Channel 2
Length of feeder cable ________ m
Length of feeder cable ________ m
Size of wire used (mm
2
or AWG) _____________
Size of wire used (mm
2
or AWG) _____________
(should be 1.5 mm
2
or larger)
Type of wire insulation _____________________
Type of wire insulation _____________________
Thickness of insulation:_____________ mm
Thickness of insulation:____________ mm
Type of feeder cable used (screened, armoured, multicore, etc.)
Summary of Contents for PD230 Enhanced Vehicle Detector
Page 6: ...302UM0017 Rev 01 PD230 Enhanced Detector User Manual Page 6 of 37...
Page 12: ...302UM0017 Rev 01 PD230 Enhanced Detector User Manual Page 12 of 37...
Page 18: ...302UM0017 Rev 01 PD230 Enhanced Detector User Manual Page 18 of 37...
Page 22: ...302UM0017 Rev 01 PD230 Enhanced Detector User Manual Page 22 of 37...