background image

1

9

7

5

6

4

2

10

3

8

SE 

Series

Steam

Exchange

Humidifiers

Capacity up to 1050 lbs/hr 

  NORTEC Total Controller 

  Intuitive scale management 

based on steam production  

All components suitable for  
RO or DI water 

Internal water tempering for 
drain water cooling 

Fully modulating 

Built-in float and 
thermostatic steam trap(s)

Built-in P-trap

Fully insulated tank for 
efficient operation 

Pre-cleaning sequence 
ensures shorter 
maintenance time

Building management 
system compatible

Network up to 10 units 

Small SE 50 lbs/hr for easy 
ceiling mounting

SETC 100

5

SE Series Features Comparison

SETC

SEP

Steam capacity adjustment 

Full size alphanumeric display and keypad

Configurable date and time indication

Transducer signal acceptance

Individual component diagnostic capability

Keypad set-point adjustment (humidity)

Display of relative humidity 

Low and high relative humidity alarms

Keep warm feature 

Networking capability up to 10 units

Pre-cleaning sequence

Troubleshooting Guide 

Self diagnostic capabilities

Fault history

Smart drain water cooling

Single or Dual modulation signal acceptance

Time to next maintenance alarm

System demand indication

Backlit display

Built-in Float & Thermostatic steam trap(s)

3-day drain with no call for humidity

Full tank blow down capability via time of   
day, timer, or signal from BMS

Remote fault indication

Industry standard modulation signal acceptance

Internal Drain water cooler

Blow down based on steam production

Precise five level water level indication

Status indicator lamps

Single or multiple steam outlet options

Large Side tank cleaning port

Top access cleaning

Single water connection 

Fully modulating down to 25% of total capacity

Options

Interaction with BMS system (Contact Factory)

Freeze protection

Floor stand

Distribution Systems

SAM-e

Steam distributor

Blower pack

Summary of Contents for Pressure Steam Humidifier

Page 1: ...Designed to deliver reliable humidity from facility steam boilers Pressure Steam Humidifiers Live Steam ...

Page 2: ...le machines work better in favorable surroundings All equipment and processes respond in various ways to temperature and humidity fluctuations For maximum performance reliable temperature and humidity are essential NORTEC LiveSteam LS Series steam injection humidifiers and NORTEC SE Series steam exchange humidifiers deliver reliable humidity from the facility steam boiler Constructed of premium qu...

Page 3: ...l heat exchanger s bringing the surrounding water in the tank to atmospheric clean steam vapor The chemical treatment from the boiler does not enter the air steam The SE Series heat exchanger utilizes 316 stainless steel and is designed to give maximum output while taking up minimal space It is easy to remove for cleaning and the flat smooth surfaces help reduce maintenance time Precise Control In...

Page 4: ...standard Pneumatic valve actuator optional 9 Tube adaptor connecting valve to dispersion tube Factory installed silencers are available 10 Steam outlet orifices sized for exact humidity output LiveSteam mounted with a SAM e manifold for short absorption distance applications Available for single or multiple tube applications Pressure ranges from 2 50 PSIG High capacity system up 3209 lbs hr Econom...

Page 5: ...f relative humidity Low and high relative humidity alarms Keep warm feature Networking capability up to 10 units Pre cleaning sequence Troubleshooting Guide Self diagnostic capabilities Fault history Smart drain water cooling Single or Dual modulation signal acceptance Time to next maintenance alarm System demand indication Backlit display Built in Float Thermostatic steam trap s 3 day drain with ...

Page 6: ...humidification center from any location worldwide using standard internet connections This advanced software shows graphic representations of the humidifier and its key parameters up to 75 functions NORTEC LINKS NORTEC Links offers monitoring and control allowing humidifier s to communicate to your Building Management System BMS The controller is factory installed and is located internally to the ...

Page 7: ...75 SE 250 SE 375 SE 475 SE 675 SE 950 SE 1050 Pressure range psig kPa 5 15 35 105 Max capacity single tube lbs hr kg hr 17 50 8 23 5 100 2 45 7 175 3 79 11 250 5 114 15 375 7 170 24 475 11 215 30 675 14 306 58 950 26 430 67 1050 30 476 Physical data Width x Height x Depth 25 6 x 20 6 x 18 4 65 1cm x 52 4cm x 46 7cm 46 4 x 32 0 x 20 0 117 8cm x 81 4cm x 50 8cm 46 4 x 32 0 x 26 4 117 8cm x 81 4cm x ...

Page 8: ... AxAir Nortec Ltd 2740 Fenton Road Ottawa Ontario K1T 3T7 Tel 1 866 NORTEC1 Fax 613 822 7964 email nortec humidity com WEBSITE www humidity com www norteconline com www nortecparts com Certificate No 002419 electric steam atomizing nozzles high pressure nozzles steam injection steam exchange gas steam Form 07 224 ...