System Maintenance
Regular maintenance is recommended per the schedule below:
NO.
DESCRIPTION
FREQUENCY
1
Inspect and clean integrity of feed horn window, replace
when damaged
Once per month
2
Inspect OMT and waveguide sealing, if there is a
leakage, dry out the components and seal with silicon
fusion tape or replace damaged parts.
Once per month
3
Inspect screws and nuts, tighten, or replace screws upon
loosening or rusting
Once per month
4
Inspect system for any noise during operation. Clean up
the transmission and lubricate if any noise
Once per month
5
Inspect paint integrity of the antenna, touch up when
required
Once per month
6
Inspect wear and tear of timing belt and lubricate gears
and transmissions. Replace when required
Once per year
7
Calibrate compass to ensure correct heading
Once per year
8
Clean the petal surface
Every 3 months or required when
exposed to extreme conditions
Factory Reset
To factory reset the terminal, perform the following steps:
1. Connect the antenna to power.
2.
While pressing ‘One Button’, press ‘On/Off’ button to turn on system.
3.
Do not release ‘One Button’ until system beeps twice.
4. The system is now reset to factory settings.
Note