Table 2-5: Command Summary
Command
Param-Value
Pairs
Response Format
(enveloping <CR><LF> characters not shown)
getident
None
<CR><LF>ok pn <Part Name> swver <Software Version> sn <Serial Number><CR><LF>
where:
<part#> = unit part number
<swver#> = software version
<serial#> = unit serial number
getstatus
None
<CR><LF>ok fault <Fault Status> fwdpwr <RF Forward Power> revpwr <RF Reverse
Power> temp <Device Temperature> unmutetime <Running Unmute Time><CR><LF>
where:
<Fault Status> = 0 (no fault) or 1 (fault condition occurred)
getfaults
None
<CR><LF>ok mute <Mute Fault> overtemp <Over Temperature Fault> pll <PLL Fault>
power <Power Fault><CR><LF>
where:
<Mute Fault> = 0 (unit unmuted) or 1 (unit muted)
<Over Temperature Fault> = 0 (temp ok) or 1 (error - over temp condition exists)
<PLL Fault> = 0 (pll ok) or 1 (error
– pll loss of lock)
resettempfault
None
<CR><LF>ok<CR><LF>
<CR><LF>err<CR><LF>
(when system temperature is above trip point)
setmute
cmd
(0|1)
0 = unmute
1 = mute
<CR><LF>ok<CR><LF>
getmuteonfault
None
<CR><LF>ok value <Mute On Fault><CR><LF>
where:
<Mute on Fault>= 1 (the device is automatically mute itself if a fault is detected) or 0 (the
device is not mute automatically)
setmuteonfault
value
(0|1)
0 = off
1 = on
<CR><LF>ok<CR><LF>
M
UTE
L
OGIC
The unit will be muted when any of the following conditions exist:
1. A software mute command is issued through the serial interface.
2. A mute command/signal is issued through the discrete SHUTDOWN line (Pin D of J2).