GB: Users manual

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A - On/Off

 

 

 

 

 

 

 

 

B - Temp +

 

 

 

 

 

 

 

 

C - Temp -

 

 

 

 

 

 

 

 

D - Function indicator Timer

 

 

 

 

 

 

 

 

E - Temperature indicator

 

 

 

 

 

 

 

 

F - Timer On/Off    

 

 

 

 

 

 

 

 

      

Continuous operation

Turn the electric cartridge on or off using the On/off button (A). LED 2-5 (E) will start flashing. 

Temperature

Set the desired temperature using the + or - buttons. (B or C). LED2-5 (E) will flash with a blue 
light. When the desired temperature is reached, LED2-5 (E) will be illuminated with a solid blue 
light.  

2-hour Timer

The electric cartridge starts and runs for two hours with set temperature. Press      Timer On/
Off (F). The function indicator (D) will be illuminated with a solid red light. The temperature can 
be adjusted while the timer function is operating by pressing the + or - buttons.

Anti-freeze function

If the towel rail is switched off and the sensor detects that the temperature has dropped below 
6°C, the towel rail switches on automatically to prevent the water inside freezing. The middle 
function indicator (E) will flash with a blue light when this function is activated. This function will 
work automatically as long as the electric cartridge has power. 

Indication of temperature

Since minimum temperature of the electric cartridge is 30 degrees 
the left temperature indicator always indicates 30 degrees. The 
other lights indicates different temperature dependent on set 
maximum temperature.

Calibrating maximum temperature

The electric cartridge is delivered with a standard maximum temperature of 60degrees. It is 
possible to adjust the maximum temperature in 5 degrees increments between 45 to 60 de-
grees

In order to modify the maximum temperature, unplug the device and
 plug it back in, while pressing       button. A single diode will start 
flashing on the display panel. Use + and - buttons to set one of the 
5 possible maximum temperatures. The first diode stands for 
45 degrees and then increases with 5 degrees for each diode. 
The last diode stands for 65 degrees.
After selecting the new maximum temperature press on/off button to store the new setting.

A

B

C

D

E

F

Summary of Contents for 0863

Page 1: ...Monteringsanvisning Installasion Asennusohjeet Installation Instruction manual 1 10 Vers 2018 06 01 TERMA Art nr 0863 230V 50Hz 300W IP x5 G1 2 ...

Page 2: ...uppstå Se sida 6 för instruktion om hur man ställer in maxtemperaturen DK Sikkerhedsanvisninger Dette produkt må kun anvendes af børn fra 8 års alderen og af personer med nedsatte fysiske sensoriske og mentale evner eller manglende erfaring og viden forudsat de er under opsyn eller er blevet instrueret i at bruge produktet på en forsvarlig måde og forstår farerne derved Produktet skal holdes uden ...

Page 3: ...så varm at det kan oppstå brannskader Se side 8 for instruksjon om hvordan man stiller inn makstemperaturen FI Turvallisuusohjeet Tätä tuotetta ei suositella ilman asianmukaista valvontaa sekä opastusta laitteen turvalliseen käyttämiseen alle 8 vuotiaille lapsille eikä henkilöille joiden fyysiset aistinvaraiset tai henkiset ominaisuudet ovat alentu neet Tuotetta ei ole tarkoitettu lapsille Laittee...

Page 4: ...dance with regulations for electri cal safety Including regulations concerning residual current devices and permissible locations If the heating element is connected to power when the towel warmer is not filled with water or the water level is to low the thermal fuse will be damaged The warranty is not valid in this case Do not open the device any interference with internal components or power cor...

Page 5: ...4 10 5 10 2 3 G1 2 Alt Vaiht 22mm 4 5 1 H O 3 5cm Max Temp 2h H O 2cm ...

Page 6: ... funktion är aktiv Denna funktion fungerar automatiskt när elpatronen är strömförsörjd Temperaturindikering Då värmarens minsta inställbara temperatur alltid är 30 grader markerar den vänstra temperaturindikerings lampan alltid 30 grader De övriga lamporna indikerar olikatemperatur beroende på vilken maxtemperatur värmaren är inställd på Inställning av maxtemperatur Värmaren levereras med maxtempe...

Page 7: ...eringen E blinker blåt Denne funktion fungerer automatisk så længe el patronen er strømforsynet Temperaturindikering Da vermerens laveste stilbare temperatur er 30 grader viser den venstre doiden altid 30 grader De andre diode viser forskellige temperaturer afhængig af valgt maxtemperatur Justering af max temperaturen Vid leverering av varmeren er den indstillet till maksimal 60graders temperatur ...

Page 8: ...aktiv Denne funksjonen fungerer automatisk når elpatronen er tilkoblet strøm Temperaturindikering Da håndkletørkerens minste justerbare temperatur alltid er 30 grader markerer den venstre temperaturindikeringslampen alltid 30 grader De andre lampene angir forskjellige temperaturer avhengig av hvilken maks temperatur håndkletørkeren er innstilt på Instilling av makstemperatur Elpatronen leveres med...

Page 9: ...n sinisistä valoista E vilkkuu kun toiminto on käynnissä Tämä toiminto on automaattinen aina kun pyyhekuivain on kytkettynä sähköön Lämpömittari Vasemmanpuoleinen lämpötilan merkkivalo näyttää aina 30 astetta joka on vastukselle asetettava minimilämpötila Muut merkkivalot ilmaisevat eri lämpötiloja riippuen siitä mikä on asetettu maksimilämpötilaksi Maksimilämpötilan asetus Sähkövastuksen tehdasas...

Page 10: ...e freezing The middle function indicator E will flash with a blue light when this function is activated This function will work automatically as long as the electric cartridge has power Indication of temperature Since minimum temperature of the electric cartridge is 30 degrees the left temperature indicator always indicates 30 degrees The other lights indicates different temperature dependent on s...

Reviews: