Norman Allure C1000 Operation Instruction Download Page 2

 
 

2.  Setting Output Power Level 

 

 

To ensure that the color temperature of the resulting light will remain as stable as possible and yet 
provide output power selections at the same time, the Constant Light has been designed to 
accommodate two lamp bulbs, #1 and #2 respectively, controlled by independent on/off Switches. 

 

 

Three different levels of output power can be selected conveniently by flipping the on/off switches for 
the two lamp bulbs as follows – 
 

  

Output 

Power 

 Level 

Lamp #1 Switch 

Lamp #2 Switch 

 

  

350W 

ON 

OFF 

 

  

650W 

OFF 

ON 

 

  

1000W 

ON 

ON 

 

 
 

 

 

3.  Glass Dome – Material, Installation and Removal 

 

 

3.1.  The Glass Dome is made of Pyrex, which is heat resistant. 

 

 

 

 

3.2.  There are three pieces of stainless steel Spring Plates installed evenly around the perimeter of 

the Reflector. The Spring Plates are bending slightly inward towards the center of the Reflector 
and each of them has a catch at the tip for holding the Glass Dome in place. 

 

 

 

 

3.3.  All installation and removal of the Glass Dome must only be carried out after the light has been 

disconnected from power and the Glass Dome has cooled down completely. 

 

 

 

 

3.4.  To install the Glass Dome, take the following steps – 

 

 

 

 

 
 

Summary of Contents for Allure C1000

Page 1: ... read these instructions carefully before starting to use the light 1 Main Parts The external constituent parts of the light are as follows 1 Reflector Installation Screw 7 Fuse 2 Spring Plates for Glass Dome Installation 8 Lamp On Off Switches 1 2 3 Quartz Lamp Bulbs 9 AC Power Cord Socket 4 Glass Dome 10 AC Power Cord 5 Reflector 11 Handle 6 Mounting Bracket ...

Page 2: ...mp 1 Switch Lamp 2 Switch 350W ON OFF 650W OFF ON 1000W ON ON 3 Glass Dome Material Installation and Removal 3 1 The Glass Dome is made of Pyrex which is heat resistant 3 2 There are three pieces of stainless steel Spring Plates installed evenly around the perimeter of the Reflector The Spring Plates are bending slightly inward towards the center of the Reflector and each of them has a catch at th...

Page 3: ...e the Glass Dome a Press the Glass Dome in the direction of one of the three Spring Plates and then tilt it slightly so that the locking tips of the other two Spring Plates will slip out of their respective locking holes b Press the Glass Dome towards the other two Spring Plates avoiding their tips from going back into their respective locking holes and then pull the dome out slightly to let the t...

Page 4: ...ains irregardless whether the Lamp Switches are on or off Thus when the light is not needed and turned off it is advisable to pull it off the power mains as well 7 Technical Specifications The specifications are slightly different dependently on the operating voltage Operating Voltage AC110V 120V 50 60 Hz Quartz Lamp Bulb 350W 650W Safety Protection a Thermal Switch b 10A Fuse c Glass Dome Color T...